9
Safety distance when installing the appliance near a wall with
additional niche cladding
There must be a minimum distance of 50 mm between the niche cladding and the worktop cut-out.
This distance is only necessary for niche cladding made of wood or any other combustible material.
For non-combustible materials (metal, ceramic tiles or similar), this dimension can be reduced by the
thickness of the niche cladding material. The materials can warp or distort when subjected to high
temperatures.
Example: thickness of the niche cladding 15 mm
50 mm - 15 mm = minimum distance 35 mm
(1) Wall
(2) Niche cladding
measure x = thickness of the niche cladding
(3) Worktop
(4) Worktop cut-out
(5) Minimum distance
for combustible materials 50 mm
for non-combustible materials 50 mm -
measure x
SAFETY INSTRUCTIONS FOR INSTALLATION
wORKTOP CUT-OUT DIMENSION
520
495
355
380
65