background image

 

start up screw to take the crushed ice after ice-valve opened. The taking ice will 

be   stopped once it leaves from the switch of dispenser   

The crushed ice is default mode when power on at first time. 

1.2.2 

Dispensing ice cube

 

Choose the ice cube button on DOM, and then, press the switch of dispenser, 

start up electromagnet and screw to take the ice cube after ice-valve is opened. 

The taking ice stops once it leaves from the switch of dispenser   

1.2.3 

Dispensing water

 

Choose the water button on DOM, and then, press the switch of dispenser, start 

up water-valve to take the cooling water from fridge. The taking water stops once 

it leaves from the switch of dispenser 

1.2.4 

 Dispenser light

 

Press the switch of dispenser

LED light. The light will close if the switch of 

dispenser is closed after 2s. 

1.2.5 

Alarm for lacking water

 

After filling water for ice-marker is end, if temperature rise of ice-marker sensor is 

less than 5

 within 3 minutes, the buzzer will be activated and alarm 1 time per 

30s within 5 minutes, later, it will alarm 1time per 1 hour . 

1.2.6 

 Fault of ice-marker sensor   

The ice-marker will stop if the sensor of ice-marker occurs fault, "ER IC" of fault 

code    will be displayed on DOM. After the fault is removed ,the ice-marker will 

be run   according to initial program   

   

1.2.7 

Start program 

 

Time 

               

 

  Parts                         

 

 

 

Power        (W

 

   

 

  0~12s           level position of ice-marker reset                        

  -- 

     

 

13~16s           heater of dispenser                                      

 

3.5 

     

 

17~20s           heater of chute flap                                      

 

0.5 

   

 

21~23s           heater of tube for filling in water                           

    4 

     

 

24~25s           motor of flap                                  

 

 

 

 

    3 

   

 

26~27s  

  electromagnet of choosing ice                                 30~50   

 

Summary of Contents for CAFF206SS

Page 1: ...CAFF206SS Caple Side by side Fridge Freezer Caple Side by side Fridge Freezer Service Manual ...

Page 2: ...ch Buttons 2 2 Output signal 2 2 1 Loads output 3 DOM contents and rule 3 1 Interface of DOM 3 2 Temperature setting function for F comp and R comp 3 3 Child lock 3 4 Supper freezing 3 5 Display rule of DOM 4 Others program 4 1 Fault checking program 5 Additional content for IWD 5 1 Work steps of IWD 5 2 Control program of dispenser ...

Page 3: ......

Page 4: ...l 2 2 1 Loads output No Parts Controlling mode 1 compressor Run stop 2 condenser fan Run stop 3 F compartment fan 2 shifts speed 4 R compartment LED lamp Run stop 5 F compartment LED lamp Run stop 6 IWD LED lamp Run stop 7 DiD heater Run stop 8 Defrost heater Run stop 9 Damper Run stop 10 Damper heater Run stop 11 DOM and Buzzer According to PCB 12 Motor of ice marker According to PCB 13 Motor of ...

Page 5: ...r freeze icon To display the super freeze 5 Fridge button To switch on the fridge and set temperature 9 Crushed ice icon To display the selected crushed ice of IWD 2 Super freeze button To switch on the super freeze 6 Lock button switch the button lock on and off 10 cube ice icon To display the selected cube of IWD 3 Freeze button To switch on the freeze and set temperature 7 Lock icon display the...

Page 6: ...nish all of lamps will be illumed only when any button is touched in the case of all of lamp close up but setting function hasn t been activated yet and then other lamps will close up at the same time if any button is pressed again 3 3 Child lock 3 3 1 The child lock button is in unlocking state when the appliance is switched on first the icon isn t displayed on DOM 3 3 2 Others button on DOM can ...

Page 7: ...temp at the same time if they happen after 3 hours 4 1 2 Fault codes and definition NO Item Fault display Fault definition Remark Freezer setting temp cooler setting temp 1 Normal setting temp display Normal display 2 F sensor abnormal Er FS F sensor break or short Check wire of sensors 3 AT sensor abnormal Er rH AT sensor break or short 4 C sensor 1 abnormal Er rS C sensor 1 break or short 5 C se...

Page 8: ...position of Ice marker shelf fill in water making ice moving ice filling in water cycle 1 1 1 Checking for reset position of Ice marker shelf 9 Communication abnormal Er CO Communication between PCB and DOM power ON D heater ON 1s 5s D heater off Damper heater ON 0 5s 5s Damper heater OFF 0 5s F fan OFF 5s Cond fan ON Com ON F fan ON H speed Cond fan ON Damper ON 0 5s 5s 0 5s 5s 0 5s Cond fan OFF ...

Page 9: ... out twice in order to ensure that the ice of shelf is moved out completely 1 1 5 Ice marker closing The shelf of ice marker will be reset to level position after the switch of ice marker is closed icing function stops The dispenser can be operated for taking ice and water 1 2 Control program of dispenser The function of taking ice and water will be stopped when F door is opened in order to avoid ...

Page 10: ...1 2 4 Dispenser light Press the switch of dispenser LED light The light will close if the switch of dispenser is closed after 2s 1 2 5 Alarm for lacking water After filling water for ice marker is end if temperature rise of ice marker sensor is less than 5 within 3 minutes the buzzer will be activated and alarm 1 time per 30s within 5 minutes later it will alarm 1time per 1 hour 1 2 6 Fault of ice...

Reviews: