NORMAL DEFROST FUNCTION
Calculating defrost starting time
a) If AT<23 C
fix the defrost cycle to 16 hours (r stopping)
b) If 23 C < AT < 30 C
If door is not opened;
First Defrost cycle time will be fixed to 20 hours
.
Second defrost cycle time will be fixed to 26 hours.
Third and following defrost cycle times will be fixed to 55 hours.
If door is opened at first defrost cycle;
Complete the defrost cycle time to 20hours and Next defrost cycle time will start from 20 hours
again (from the beginning).
If door is opened at second or following defrost cycle time, two case can be happen;
If door opened
BEFORE
20 hours in this cycle;
Complete the defrost cycle time to 20hours and Next defrost cycle time will start from 20 hours
again (from the beginning).
If door opened
AFTER
20 hours in this cycle ;
Immediately start defrost and next defrost cycle time will start from 20 hours again(from the
beginning).
c) If 30 C < AT <= 35 C ;
Defrost cycle is max. 8 hours of compressor running accumulated time.
Minimum defrost cycle time will be 16 hours (stopping)
d) AT ≥ 35 C ;
Defrost cycle is max. 12 hours of compressor running accumulated time.
Summary of Contents for CAFF45GM
Page 1: ...CAFF45GM Caple 4 door Freestanding Fridge Freezer Technical Manual ...
Page 2: ...CAFF45GM Caple 4 door Freestanding Fridge Freezer ...
Page 3: ...CAFF45GM Caple 4 door Freestanding Fridge Freezer ...
Page 4: ...CAFF45GM Caple 4 door Freestanding Fridge Freezer ...
Page 5: ...CAFF45GM Caple 4 door Freestanding Fridge Freezer ...
Page 6: ...CAFF45GM Caple 4 door Freestanding Fridge Freezer ...
Page 12: ...1 CUSTOMER SUPPORT WHITE GOODS 916 FRENCH DOOR SEPTEMBER 2015 CIRCUIT DIAGRAM ...
Page 13: ...CAFF45GM Service Manual ...
Page 23: ...Flow of Air ...
Page 24: ...ZONE 1 ...
Page 25: ...COOLER Compartment and ZONE 2 ...
Page 32: ......