12
Conversion to LPG
J
J
Fig. 3.3
Fig. 3.4
Conversion procedure
Injectors replacement
Select the injectors to be replaced
according to the “Table for the choice of
the injectors”.
To replace the injectors proceed as fol-
lows:
- Remove pan supports and burners
from the cooktop.
- Using a wrench, substitute the nozzle
injectors “J” (fig. 3.3, 3.4) with those
most suitable for the kind of gas for
which it is to be used.
The burners are conceived in such a
way so as not to require the regula-
tion of the primary air.
Minimum burner setting adjust-
ment
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even when turned quickly from
the maximum position to minimum.
The flame adjustment is done in the fol-
lowing way:
- Turn on the burner
- Turn the tap to the MINIMUM position
- Take off the knob
- With a small flat screwdriver turn the
screw inside the tap rod to the correct
regulation (fig. 3.5).
Normally for G30/G31, the regulation
screw is tightened up.
Fig. 3.5