Instruction manual CR9209
13
Please keep this instruction manual for future reference
Burner and injector characteristic table Burner and injector characteristic table
(*) = With dry gas and with greater calorific power (Hs) at 15 and 1013.26mbar
INSTRUCTIONS FOR USE
GAS BURNERS
Description of the main parts of the appliance
WARNING:
Read the instructions before installing or using this appliance.
- This appliance should be installed in accordance with current regulations and should only be used in a well ventilated
spaces. Do not use the appliance in a garage, basement and a room without windows, etc.
- Using a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure
that the kitchen is well ventilated: keep windows or doors open or use some form of extraction
- Prolonged intensive use of the appliance may require additional ventilation, for example opening a window, or for more
effective ventilation, increase power level of extractor.
1 = pan support
2 = burner cap
3 = burner head
4 = spark plug
5 = safety valve
6 = control knob
Burner
By-pass
(mm)
Consumption (*)
LPG
I3B/P(30)
G30
G30
G31
G20
I3+(28-30/37)
Natural gas I2H
Input
kw(g/h)
Main
injector
(mm)
Input
kw(g/h)
Main
injector
(mm)
Input
kw(g/h)
Main
injector
(mm)
Input
kw(g/h)
Main
injector
(mm)
1
2
3
4
Rapid
Semi-rapid
Auxiliary
Triple ring
0.44
0.44
0.44
0.44
3.0 (218)
1.75 (127)
1.0 (72.7)
3.7 (269)
0.85
0.65
0.50
0.95
3.0 (218)
1.75 (127)
1.0 (72.7)
3.7 (269)
0.85
0.65
0.50
0.95
3.0 (214)
1.75 (125)
1.0 (71)
3.7 (264)
0.85
0.65
0.50
0.95
3.0
1.75
1.0
3.7
1.18
0.97
0.72
1.40
Test point pressure
G30: 29mbar
G30: 29mbar G31: 37mbar
20mbar
4
3
2
1
2
CR9209 - Instruction Manual.indd 13