Instruction manual DD901BK 13
Please keep this instruction manual for future reference
We decline any responsibility in case of accidents caused by a lack of ground connection or
incorrect ground connection. The appliance must be fed through a differential protection device
(RCD), with a nominal residual current not exceeding 30mA. If the power cord is damaged,
call Caple service to avoid any risk.
WARNING:
The downdraft connection to the electrical network must be carried out only by
professional and qualified technicians.
The downdraft must be connected to a properly installed and suitable electrical network.
The electrical system must comply with VDE0100 standard.
DANGER:
If the downdraft presents any anomaly, disconnect the appliance or remove the fuse
corresponding to the appliance power disconnecting line.
If the appliance has no plug or if the plug is not easily accessible, then a device needs to be fitted
to cut it off from the electric network; this device must have an opening distance between contacts
on all poles of at least 3mm.
E L E C T R I C A L C O N N E C T I O N
While installing the appliance and carrying maintenance operation, make sure it is disconnected
from the electrical network or the fuses are cut out or removed.
Check that:
»
Power is enough.
»
Feeder lines (mains) are in good conditions.
»
The cables diameter complies with installation regulations.