background image

5

C

ontents

Dimensions 

6

Installing the 

extractor

7

Grease filter removal, installing the activated charcoal filter 

        8

        9

10

12

13

Electrical connection   

How the downdraft works 

Cleaning the extractor 

Troubleshooting 

Aftersales service 

13

Summary of Contents for DD910BK

Page 1: ...Model code DD910BK DD910SS DD910WH Instruction manual for downdraft hood Contact Caple on 0844 800 3830 or for spare parts www caple co uk ...

Page 2: ......

Page 3: ...ealth which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product This appliance is marked according to the European directive 2002 96 EC on waste electrical and electronic equipment WEEE CE Declara...

Page 4: ...ance Frying under the appliance must be done under constant supervision as hot oils and fats may ignite Respect the guidelines for cleaning and replacement of grease filters Accumulated deposits of grease are a fire hazard This appliance must not be with over cook tops powered by wood or coal or in any case with cook tops with power levels that could damage the appliance Never use steam or high pr...

Page 5: ...sions 6 Installing the extractor 7 Grease filter removal installing the activated charcoal filter 8 9 10 12 13 Electrical connection How the downdraft works Cleaning the extractor Troubleshooting Aftersales service 13 ...

Page 6: ...6 Dimensions INC ...

Page 7: ... as shown in Fig 2 5 Fix the downdraft inside the cabinet using the special fixing brackets supplied with the product Fig 3 Insert the brackets in the lower side of the downdraft Fig 3 in such a way that there is a 2 mm distance between the lower side of bracket and the bottom of the cabinet Fig 3 This distance will allow the traction to be po sitioned downwards of the product at the moment of fix...

Page 8: ...is case it is necessary to connect the exhausting channel ducting to the outside exhausting pipes are not supplied with this product Check for a non return valve blockage In case of outside air discharge installation fit a non return valve to prevent wind and back air from entering Recirculating mode In case fumes and vapour cannot be evacuated outside the appliance can be used in the recirculatin...

Page 9: ...pliance is fitted with an H05 VVF 3 conductor 0 75 mm2 neutral phase and ground power cord This can be connected up to a 220 240 V mono phase electrical network through a CEI 60083 approved power socket which must remain accessible after installation in compliance with installation regulations We decline any responsibility in case of ac cidents caused by a lack of ground connec tion or incorrect g...

Page 10: ...tor close the carriage and switch the lights off if they are on The set function is signalled by the flashing LEDs D for the set speed The timer can be cancelled by press ing the key again Other functions Automatic turn off After 4 hours of continuous working from the last function selection the appliance turns off and closes automatically Grease filters saturation After 30 hours of working the sp...

Page 11: ...tey system If there is an obstacle while the extractable unit is closing the Downdraft stops closing and rises again thanks to a security system WARNING This operation has to be carried out by a specialised technician ...

Page 12: ...e cleaned on a regular basis because otherwise they may represent a fire risk Refit the grease filters and front panel making sure that the panis properly fitted at the sides so that it it does not cause the downdraft to stop operating Active charcoal filter In the recirculation mode the active charcoal filter must be replaced periodically To remove the charcoal filter first of all it is necessary...

Page 13: ...er is not worn out filtering version cooker hood The air outlet channel is free and compliant with paragraph no 2 The non return valves of the suctioning unit are free to rotate The cooker hood stops in the middle of operation Check that There is not a power outage The omnipolar device has not tripped Any maintenance operation on your appliance should be carried out by Either your retailer Or anot...

Page 14: ...14 ...

Page 15: ...15 Images ...

Page 16: ...16 2 mm 2 6 3 4 5 1 ...

Page 17: ...17 9 8 7 10 11 12 ...

Page 18: ...18 10 09 90002103999 N 220 240V 50 HZ ATTUATORE 12Vcc 68W MAX 68W TYPE FSEE EQUIPMENT S 002 EM_TC X22 Q3 X0 90002002001 A C B 13 ...

Page 19: ......

Page 20: ......

Page 21: ...Caple Fourth Way Avonmouth Bristol BS11 8DW www caple co uk 90002422415 GM 02 12 ...