REPAIRS
REPLACING THE POWER SUPPLY CABLE
For 2 electrical plate model
Turn the cook top over and unhook the terminal board
cover by inserting a screwdriver into the two hooks "A" (fig.
8.1). Open the cable gland by unscrewing screw "F" (fig.
82), unscrew the terminal screws and remove the cable.
The new supply cable, of suitable type and section, is
connected to the terminal board following the diagram fig.
8.3.
REPLACING THE POWER SUPPLY CABLE (for gas
models)
The supply cable must be replaced with a cable of the
same type. - The electrical cable must be connected to the
terminal board following the diagrams of fig. 8.4.
FEEDER CABLE SECTION
GAS HOB type "H05V2V2-F"
resistance to temperatures of 90°C
230 V-
3 x 0,75 mm
2
ELECTRIC HOTPLATES
The external diameter of the supply cable must not be
more than 9 mm.
type "H05RR-P'
230 V--
3 x 1,50 mm2