14 Instruction manual RiF1796
Please keep this instruction manual for future reference
V E N T I L AT I O N R E Q U I R E M E N T S
The main consideration when installing
a refrigeration product into a cabinet is
ventilation. The heat removed from the
appliance needs to be dissipated into the
room. Failure to correctly ventilate the
product can result in increased running
costs and premature failure. It will also
invalidate the guarantee provided with
the appliance.
An air intake in the plinth is required to
allow for the correct air flow (recommended
500mm x 40mm). If preferred a decorative
stainless steel plinth grille is available,
product code: GRILL/ SENSE600.
This can be purchased from your retailer or
www.caple.co.uk.
To ensure the correct operation of the
appliance it is important the top of the
housing is not blocked off. The top of
the cabinet needs to be vented into the
room,the recommended minimum size of
the vent opening is 500 x 40mm.
There should also be space at the rear
of the cabinet to allow the cool air to be
drawn over the condenser. This should also
be at least 500mm x 40mm. The more air
available to circulate the product, the more efficiently it will operate.
NOTE:
Installation instructions are supplied with the appliance in a separate document. Only the solid
metal fixing bracket is included (part 1a) for installation.
23
min.
40m
m
Ventilation space at
rear to allow heat
dissipation from the
condenser
Plinth ventilation
min. 200cm2
Air flow
Air flow
min. 40mm
RIL1795_Larder Instruction Manual.indd 23