• EMPTYING THE CONDENSER TANK
23
22
EN
EN
6 / REGULAR MAINTENANCE
90 cm maxi
Fig. 24
Fig. 22
Fig. 23
To avoid having to empty the collection tank
every time you use the appliance, you have a
kit (*) for removing the water from the conden-
ser directly into the drain (hose and deflector).
To fit this :
— Take off the existing pipe and push it inside
the appliance
(Fig. 22).
— Clip the deflector with the top of the pump
(Fig. 23).
— Connect the hose from the kit to the end
connector on the appliance
(Fig. 24).
You can connect the other end of the hose
either :
- To a ventilated trap
(Fig. 25)
.
- Or a sink trap
(Fig. 26).
When connecting to a trap, you must remove
the filler plug. Then press home the rubber tip.
If necessary, add a clamp connection
(Fig. 26)
.
Important :
The deflector must necessarily be posi-
tioned before the drain hose connection to
avoid any water splashes when taking off the
hose.
Remarks :
Directly emptying the condenser water
into the sewage system will prevent the
reuse of the recovery water for steam pro-
grams.
Fig. 26
Fig. 25
• DIRECT EVACUATION OF WATER CONDENSER
Déflecteur
Encart
Tuyau
Remarks :
(*) This kit is provided
with the appliance or is available near
your After-sales service under the ref.
57X3184 (according to model).
Deflector
Hose
Insert
6 / REGULAR MAINTENANCE
Important :
The dryer must not operate without the
filter.
Important :
Please remember that the filter must
be cleaned after every drying or steam cycle.
This is located in the lower part of your dryer.
Clean it as follows :
— Remove it from its housing by pulling it
upwards
(Fig. 16).
— Open the filter
(Fig. 17).
— Clean it by removing the thin coating of lint
covering it
(Fig. 18).
Ensure that there is no lint accumulating
round the dryer.
Important :
Do not wash filter with water.
(Fig. 19)..
— Re-insert it in its housing, pushing it well in.
Fig. 16
Fig. 17
Fig. 18
Fig. 19
This is located at the top of your appliance. It
collects the water extracted from your items
as they are dried.
— To empty it, release it from its housing by
pulling it towards you
(Fig. 20)
.
— Empty the tank or recover the condensation
container
(Fig. 21)..
Important :
The condenser tank must be emptied
after each drying cycle.
Important :
Risk of frost : if there is a risk of frost,
empty the condenser tank.
Fig. 20
Important :
Empty the condenser tank if you wish to move or tilt your appliance.
Advice :
You can store the recovery tank water in a separate container. You can later use this water
to fill the “Steam” tank.
Fig. 21
• CLEANING THE FILTER