Instruction manual ZEL900 ZEL900GM
10
Please keep this instruction manual for future reference
I N S TA L L AT I O N
P R E PA R E F O R T H E I N S TA L L AT I O N :
If you have an outlet to the outside, your cooker hood can be
connected as per the below picture by means of an extraction duct
with an interior diameter of 150mm.
Before installation, turn the unit off and unplug it from the outlet.
The cooker hood should be installed so that there is a space of
650-760mm from the centre of the mesh grease filters to the hob
(435-545mm from the bottom of the hood to the hob). It is the
manufacturer of the hob who determines the clearance required
and the clearance quoted by the hob manufacturer must be
followed. In the absence of any instructions supplied with a gas
hob, the minimum distance between the hob and the centre of the
mesh grease filters must be at least 760mm.
WARNING:
The width of the extractor hood must correspond with at least the width of the hob fitted below.
When installed above a gas hob or range cooker, do not use all the gas burners simultaneously
for prolonged periods of time at the maximum setting (max. 15mins). There can be a risk of burns
if the housing or extractor surfaces become hot, and there is also a risk that the extractor can
become damaged due to excessive heat. If 3 or more burners are used simultaneously, operate the
extractor at the maximum setting.
Never operate the gas hob without pans situated on the burners as the excess heat can damage
the extractor.
4
Earthed Outlet Box
Earthed Plug
Earthed Outlet
435-545mm
650-760mm