Fig. E1
Fig. D1
D.
DUST COLLECTION BAG
ASSEMBLY
1.
Fasten the dust collection bag on the
canister filter with a bag clamp.
Fig. D1
E.
FINAL ASSEMBLY
The main impeller housing is heavy and will
require a total of three people to complete this
final assembly.
1.
With the assistance of 2 additional
people, lift the main impeller housing
from its inverted packaged position,
flip over and position it on top of the
installed side support brackets.
2.
While it is being held in place, adjust as
required and fasten the main impeller
assembly to the support brackets with
the M8x20 bolts.
Fig. E1A
3.
The Cyclone funnel is attached to
the underside of the impeller housing
with internal bolts. You may need to
separate the lower cone from the upper
section to allow easy access to the bolt
positions. Separate these two sections
by removing the circular steel clamp.
4.
Re attach the lower cone ensuring the
flat faces of the drum lid tangs are facing
outwards.
ASSEMBLY
A
B
C
!