CARBATEC.C OM.AU
21
DC-1200P
ASSEMBLY
L.
MACHINE TESTING
Once assembly is complete, test run the machine to ensure it is properly connected to power and safety
components are functioning correctly. If you find an unusual problem during the test run, immediately
stop the machine, disconnect it from power, and fix the problem BEFORE operating the machine again.
DO NOT start machine until all preceding setup instructions have been performed.
Operating an improperly set up machine may result in malfunction or unexpected results that can
lead to serious injury, death, or machine/property damage.
1.
Clear all setup tools away from machine.
2.
Lock all swivel casters on base stand and dust collection drum.
3.
Connect dust collector to a machine or place cover over one inlet adapter port.
DO NOT operate the machine without first connecting it to a machine or covering one inlet adapter
port. Otherwise, the lack of airflow resistance will cause the motor to operate at full amperage load,
which could trip your circuit breaker or blow a fuse.
4.
Connect machine to power.
5.
Standing away from intake port, press button “ON” to turn machine on.
6.
Verify motor starts up and runs smoothly without any problems or unusual noises.
7.
Press “OFF” button to turn machine OFF.