A-2 INSTALLATION A-2
Chart gives max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle) (Example; 200A@35%
for DC Stick and 250A@35% for AC/DC Balance TIG)
TIG
STICK(MMA)
(1)
Wiring and protection based on the IEC60974.1 National Electric Code: Use a Super Lag type fuse or circuit
breaker with a delay in tripping action. Models with NEMA 6-50P plug may be used with a 50 amp protected
6-50R receptacle, or with a maximum 70 amp protected 6-50R receptacle if dedicated for the welder.
120 140 160 180 200 220 240 260
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0
OUTPUT AMPS
OUTPUT AMPS
%DUTY CYCLE
Using standard input cable for protected input supply