D-4 TROUBLESHOOTING D-4
Observe all Safety Guidelines detailed throughout this manual
TIG MODE PROBLEMS
PROBLEMS (SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED COURSE
OF ACTION
Machine output is
intermittently lost. Gas flow
and high frequency are also
interrupted.
1. Problem may be caused by high
frequency interference. Make sure that
the machine is grounded properly
according to the installation
instructions. If there are other high
frequency sources in the area, make
certain that they are grounded
properly.
2. Check Ampcontrol for proper operation
and loose connections.
3. Check for proper input voltage and
proper voltage reconnection.
Arc "Flutters" when TIG
welding.
1. Tungsten electrode may be too large
in diameter for the current setting.
2. Tungsten not "sharp" when welding in
DC - mode.
3. Gas shielding may be insufficient.
Increase gas flow; reduce tungsten
stick out beyond gas cup.
4. Check for contaminated gas or leaks in
the gas line, torch, or connections.
5. If a helium blend is used as a shielding
gas, then reduce the percentage of
helium.
Arc "Pulsates" when AC TIG
welding.
1. Micro Switch mounted on Polarity
Switch is not opening in "AC" mode.
If all recommended possible
areas of misadjustment
have been checked and the
problem persists, Contact
your local Authorized Field
Service Facility.
Note:Both the Hand and
Adjustable foot control
work in a similar manner. For simplicity, the following
explanation will refer only to "Ampcontrol", meaning both Foot and Hand models
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you
proceed.