15
- Single phase motor housed in a cast aluminium case with incorporated
overload protector .
- External carter in extruded aluminium.
- Release mechanism components in shockproof plastic.
- Geared motor with steel gears enclosed in a die cast two-piece alu-
minium shell (
BL203-202L-202C
).
- Silent running epicycloid reduction motor with a never ending universal
ball screw in steel (
BL352-452
).
- Brackets and accessories in zinc-plated steel.
- Lubrication using permanently fluid grease.
ACCESSORIES
206/BL201STAP
- Adjustable rear bracket for fitting to a wall
206/BL201SUAR
- Adjustable rear plate for fitting to a gate
980/XLSE11C
- Electric locking device 12 Vac
Attention!
Only for EU customers -
WEEE marking
.
This symbol indicates that once the products life-span has
expired it must be disposed of separately from other rubbish.
The user is therefore obliged to either take the product to a
suitable differential collection site for electronic and electrical
goods or to send it back to the manufacturer if the intention is
to replace it with a new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and
disposal contributes to avoiding negative effects on the ambient and
consequently health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and
will be dealt with according to the laws and standards of the individual
member nation.
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred
using the supplied release key (see manual release).
Periodically check the moving parts for wear and tear and grease if
required, paying particular attention to the never ending screw pos. 11
fig. 3 (
200/BL203C - 200/BL203CE
), using lubricants which maintain their
friction levels unaltered throughout time and are suitable for temperatures
of
-20 to +70°C
.
In case of failure or operational anomalies switch off the power at the
mains do not attempt to repair the appliance yourself.
Periodically check the correct operation of all safety devices (photoelectric
cells etc.).
Eventual repair work must be carried out by specialised personnel using
original spare parts.
The appliance is not suitable for continuous operation and must be
adjusted according to the model (see technical data on page 28).
The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children.
Before starting the installation of the system check that the structure
which is to be automated is in good working order and respects the local
standards and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary rein-
force the structure) and that the runner guides slide easily.
You are advised to grease all the moving parts using lubricants which
maintain unaltered friction characteristics over a period of time and are
suitable for temperatures of
-20
to
+70°C
.
• Check the safety measures between the fixed and moving parts:
- a minimum space of
30 mm
must always be left along the entire dis-
tance between the gate and the support column measured throughout
the entire opening angle of the gate.
IMPORTANT SAFETY INSTRUCTIONS
• These instructions are aimed at professionally qualified "
installers of
electrical equipment
" and must respect the local standards and regu-
lations in force. All materials used must be approved and must suit the
environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has been
made. "i.e.
for the automation of hinged gates
" with one or two gate leaves.
• The unit may be fitted both to the
right
and to the
left
of the passageway.
This product and all its relative components has been designed and
manufactured by Cardin Elettronica who have verified that the product
conforms in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper danger-
ous and the complete responsibility of the installer.
Caution!
mechanical stop buffers must be installed in both the
opening and closing positions (pos. 1, 2, 3, fig. 11).
It is the responsibility of the installer to make sure that the following public
safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the
main road to eliminate possible traffic disruptions.
2) The operator must be installed on the inside of the property and not on
the public side of the gate. The gates must not swing outwards onto a
public area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the gate at
all times.
5) At least two warning signs (similar to the example on
the right) should be placed, where they can be easily
seen by the public, in the area of the system of auto-
matic operation. One inside the property and one on
the public side of the installation. These signs must be
indelible and not hidden by any objects (such as tree
branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/
or pets must not be allowed to play within the area of
a gate installation. If possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within
at least 500 mm
of a fixed
structure the space must be protected by an anticrush buffer.
8) A correct earth connection is fundamental in order to guarantee the
electrical safety of the machine.
9) You are advised to protect the sistem's lateral access points with pairs of
(FTCS)
photocells connected to the stop input, see installation example,
component 14 on page 2.
10) If you have any questions about the safety of the gate operating system,
do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
200/BL203
Self-locking electromechanical operator suitable for hinged
gates up to
2,0
metres in length and
150 Kg
in weight (per gate leaf).
200/BL203L
Self-locking electromechanical operator suitable for hinged
gates up to
2
metres in length and
150 kg
in weight (per gate leaf).
If used with the maximum travel distance an opening angle of
90°
and
the addition of an electric locking device, it can be used for gates up to
4
metres in length and
150 kg
in weight.
200/BL203C - 200/BL203CE
Self-locking electromechanical operator
suitable for hinged gates up to
1,8
metres in length and
150 kg
in weight
(per gate leaf).
If used with the maximum travel distance an opening angle of
90°
and
the addition of an electric locking device, it can be used for gates up to
3
metres in length and
150 kg
in weight.
200/BL352
Reversible electromechanical operator suitable for hinged
gates up to
3,5 m
in length and
300 kg
in weight (per gate leaf).
200/BL452
Reversible electromechanical operator suitable for hinged
gates up to
4,5 m
in length and
300 kg
in weight (per gate leaf).
INSTALLATION INSTRUCTIONS
IMPORTANT REMARKS
IMPORTANT REMARKS
IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
USER INSTRUCTIONS
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
WARNING