14
Attention!
Only for EU customers
-
WEEE
marking
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differential
collection site for electronic and electrical goods or to send it
back to the manufacturer if the intention is to replace it with a new
equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and will
be dealt with according to the laws and standards of the individual member
nation.
• These instructions are aimed at professionally qualified "
Installers of electrical
equipment
" and must respect the local standards and regulations in force.
All materials used must be approved and must suit the environment in which the
installation is situated.
• All maintenance operations must be carried out by professionally qualified technicians.
Before carrying out any cleaning or maintenance operations make sure the power is
disconnected at the mains and that the
24V
battery supply connection
J1
has been
disconnected.
• This appliance must be used exclusively for the purpose for which it has been made.
"i.e.
for traffic control
" of passageways with widths of
3
to
8 m
.
Attention!
The appliance has a total weight of about
60 kg
therefore you must use
mechanical lifting equipment when transporting or installing.
• This product and all its relative components has been designed and manufactured
by
Cardin Elettronica
that has verified that the product conforms in every aspect to
the safety standards in force. Any non authorised modifications are to be considered
improper and therefore dangerous.
The manufacturer accepts no liability for situations arising from the use of an electrical
installation which does not conform to the local standards and regulations in force and
in particular when the earthing circuit is not efficient.
It is the responsibility of the installer to make sure that the following public safety conditions
are satisfied:
1) Ensure that the barrier installation is far enough away from the main road to eliminate
possible traffic disruptions.
2) The barrier must be installed on the inside of the property and not on the public side
of the property. The booms must not swing outwards onto a public area.
3) The barrier is designed for use on installations through which vehicles are passing.
Pedestrians should use a separate entrance.
4) The controls (including emergency commands) must be installed at a height between
1,5
and
1,8 m
and at a minimum distance of
1.83 m
(
6 ft
) from any moving part of the
barrier. Controls installed externally must be protected by a safety device inhibiting
unauthorised use. An emergency button 'STOP-RESET' (see figure 11) must be
installed within sight of the automatic system and when actived must not permit the
barrier to move again.
5) At least two warning signs (similar to the example on the
right) should be placed, where they can be easily seen by
the public, in the area of the system of automatic operation.
One inside the property and one on the public side of the
installation. These signs must be indelible and not hidden by
any objects (such as tree branches, decorative fencing etc.).
6) Do not allow children to play with fixed controls and keep
remote controls away from them. This appliance can be used
by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
7) Ahead of the automation a means of disconnection from the power supply must be
installed which has an opening distance on the contacts of all the poles and ensures
that the power supply is completely cut off under the conditions of a category III
overvoltage situation.
8) A correct earth connection is fundamental in order to guarantee the electrical safety of
the machine
9) Before installing make sure that the ambient temperature falls within the range indicated
on the appliance's data plate.
10) If you have any questions about the safety of the boom operating system, do not install
the operator. Contact your dealer for technical assistance.
Have the appliance controlled and checked at regular intervals by specialised
maintenance personnel:
-
Check
to be carried out after the first
200.000
manoeuvres (or six months after
the installation);
Periodically check the correct operation of all safety devices (photoelectric cells etc.).
Frequently examine the installation for imbalance where applicable and signs of wear
or damage to cables, springs and mounting.
Eventual repair work or maintenance must be carried out by specialised personnel
using original spare parts. The appliance is not suitable for continuous operation
and must be adjusted according to the model (see technical data on page 24).
TECHNICAL DESCRIPTION
Automation for
3 m
to
8 m
booms with a
24 Vdc
motor.
Barrier cabinet with key lock, complete with boom support and LED flashing light
built into the head of the structure plus mechanical release accessible with key
from the outside
The incorporated electronic programmer contains the power stage, the logic control,
the battery charger and the radio receiver module.
•
24 Vdc
motor with tempered steel never ending screws;
- lockable flip-back upper hood in spray-painted aluminium with built-in warning
lights;
- external manual release mechanism with key access;
- irreversible second stage reduction unit with tempered steel gears and first
stage reduction worm gear in highly reliable self-lubricating POM, mounted on
a cast aluminium stator;
- lubrication using permanently fluid grease;
- barrier cabinet made of spray-painted metal (cataphoresis passi powder
spray painting).
BOOM BALANCING SPRINGS
For the custom fit springs according to the length and weight of the boom consult
the table below. The type and number of springs remains the same however many
Cardin (ELUFS1, ELUFS1-ML, ELUMS1, ELSRS ecc.) accessories are added.
Follow the common installation drawings and those marked
with the relevant symbol indicating a barrier with a 3-5 or 6-8
meter boom.
• The barrier may be fitted both to the
right
and to the
left
of the passageway.
The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children .
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger.
During blackouts the boom can be released and manually manoeuvred (see
manual manoeuvre pag. 14).
• The ground must be stable enough to firmly hold the plinth and the anchor
plates.
• Where possible protect the barrier cabinet from accidental knocks by
passing vehicles.
• Make sure that the barrier boom arm does not move towards a rigid object
closer than
16 inches
(
406 mm
) and all pinch points between the moving
parts have been eliminated or guarded against.
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example fig. 1 pag. 2).
It is very important that the barrier be well fixed to the fastening base as
the ground anchors could loosen throughout time due to movement and
vibration and cause damage to the cabinet and the boom.
IMPORTANT SAFETY INSTRUCTION
INSTALLATION INSTRUCTIONS
WARNING
A Moving Road Barrier Can
Cause Serious Injury or Death
• The Barrier Can Be Moved Without Prior Warning.
• This Entrance Is For Vehicles Only. Pedestrians Must
Use A Separate Entrance.
• Persons Are Able To Operate The Road Barrier Only
When the Road Barrier is In Sight And Free Of
People And Obstructions.
• Do Not Let Children Operate The Road Barrier
Or
Play In The Area Of The Road Barrier.
®
ATTENTION! IMPORTANT SAFETY INSTRUCTIONS
READING THESE INSTRUCTIONS IS IMPORTANT FOR PERSONAL SAFETY. READ THE FOLLOWING REMARKS CAREFULLY BEFORE PRO-
CEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
IN THIS
ORIGINAL INSTRUCTION MANUAL. NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING
ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM. SAVE THESE INSTRUCTIONS FOR FUTURE
USE.
THE ORIGINAL INSTRUCTIONS AND RELATIVE UPDATES ARE AVAILABLE IN DIGITAL FORMAT FROM THE WEBSITE
WWW.CARDIN.IT.
Barrier trunk
Boom
Spring Colour
Nr. of springs
ELDOMSDG
CUSTOM (lengths less than 3 metres)
SP-YE
Yellow
1
DOM3 - DOM3L - DOM3AS (3 metres)
SP-GR
Green
1
DOM4 - DOM4L (4 metres)
SP-GR
Green
1
DOM5 - DOM5L (5 metres)
SP-BR
Brown
1
ELDOMLDG
DOM6 - DOM6L (6 metres)
SP-BL
Blue
1
DOM7J - DOM7JL (1 4-metre boom + 1 3-metre boom)
SP-2BR Brown
2
DOM8J - DOM8JL (2 4-metre booms)
SP-2OR Orange
2