17
The interface site must be:
- indoors (or stored in a waterproof container if installed outdoors)
- a position safe from accidental collision;
- in a position which the technician can easily reach.
Fastening
:
• Remove the two holding screws and lift up the cover
• Using the container as a template mark the four points at which the fastening holes are to
be drilled and fasten down using four self-tapping
M4
screws and relative rawlplugs (not
supplied with the kit).
• Remove the two plastic cable dividers.
Electrical connection
Warning!
The receivers must only be powered by a safety power pack. The use of non safety
power packs could provoke damage to the system.
The interface (printed circuit CS1151B) is fitted with an indoor container and has a 12-way
terminal board with the following electrical connection:
12V ac/dc
between binding posts
3-4
24V ac/dc
between binding posts
3-5
INSTALLING THE RCQ486W00 MULTIPROTOCOL INTERFACE
CS1151B DC0365
1
2 3 4 5 6 7 8 9 10
12V
0
24V
11 12
RF MODULE 433 MHz in FM
J2
J3
J4
J5
1
S1
2 3
ON
4
J2
J3 J4
J5
J1
J6
J6
1 2 3
Pos.1
1 2 3
Pos.2
J1
J2-J3-J4-J5
Pos.2
Pos.1
RS232
CON1
A
B C
D
D
A
T
A
0
/
R
C
P
CLS / AUX
GND
EN
1 2 3
Pos.3
D
A
T
A
1
/
R
D
P
27-09-2003
DC0365
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
RCQ449W00
WIEGAND