The interface has thirteen different formats for communicating with the access control device.
11 of these formats are
WIEGAND
, one is
ISO2
and the other is
SERIAL
and they can be
selected using the dip-switch "
S1
".
For a detailed description of the bit transmission sequence consult pages 21 to 23.
There are three different methods for choosing the output voltage for the formats
WIEGAND
,
ISO2 and SERIAL.
1)
12Vdc
output with jumper "
J6
" in position "
1
"
2)
5Vdc
output with jumper "
J6
" in position "
2
"
3)
TTL
Open collector output with jumper "
J6
" in position "
3
"
(open contact)
CHOOSING THE OUTPUT PROTOCOL
Pos.
1
1 2
3
J6
Pos.
2
1 2
3
J6
Pos.
3
1 2
3
J6
SELECTING THE OUTPUT VOLTAGE
DIP1 DIP2 DIP3 DIP4 PROTOCOL
ON OFF
OFF
OFF WIEGAND 26 BIT
ON OFF
ON
OFF WIEGAND 26 BIT SITE
ON OFF
ON
ON
WIEGAND 26 BIT SITE + CH
OFF ON
OFF
OFF WIEGAND 37 BIT
OFF ON
OFF
ON
WIEGAND 37 BIT + CH
OFF ON
ON
OFF WIEGAND 37 BIT SITE
OFF ON
ON
ON
WIEGAND 37 BIT SITE + CH
OFF OFF
ON
OFF WIEGAND 37 BIT D10302
OFF OFF
ON
ON
WIEGAND 37 BIT D10302 (BCD)
ON ON
OFF
OFF WIEGAND 50 BIT
ON ON
OFF
ON
WIEGAND 50 BIT + CH
OFF OFF
OFF
ON
ISO 2
ON ON
ON
ON
SERIAL
1
S1
2 3
ON
4