14
s 4HESEINSTRUCTIONSAREAIMEDATPROFESSIONALLYQUALIlED
INSTALLERS OF ELEC-
TRICAL EQUIPMENT
ANDMUSTRESPECTTHELOCALSTANDARDSANDREGULATIONS
in force. All materials used must be approved and must suit the environment in
which the installation is situated.
s !LL MAINTENANCE OPERATIONS MUST BE CARRIED OUT BY PROFESSIONALLY QUALIlED
technicians.
s 4HISAPPLIANCEMUSTBEUSEDEXCLUSIVELYFORTHEPURPOSEFORWHICHITHASBEEN
MADE
i.e. for the automation of sliding gates
WITHAMAXIMUMWEIGHTOFUP
to
3000 kg
.
s 4HEGEAREDMOTORCANBEPOSITIONEDEITHERTOTHE
left
or to the
right
of the pas-
sageway. Any non authorised modifications are to be considered improper and
therefore dangerous.
Caution!
The installation of both anti-derailment buffers
is absolutely obligatory.
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions and that the size of the gate, the
distance from the road and the work cycle speed can in no way interfere, causing
possible traffic hazards.
2) The motor must be installed on the inside of the property and not on the public
side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are pass-
ing. Pedestrians should use a separate entrance.
4) The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed at a height between
1,5
and
1,8 m
and in a location
not accessible to children. Controls installed externally must be protected by a
safety device inhibiting unauthorised use.
5) The gate must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the gate at all times.
6)
At least two warning signs
(similar to the example on the right) should be placed,
where they can be easily seen by the public, in the area of the
system of automatic operation. One inside the property and one
on the public side of the installation. These signs must be indelible
and not hidden by any objects (such as tree branches, decorative
fencing etc.). Make sure that the end-user is aware that children
and/or pets must not be allowed to play within the area of a gate
installation. If possible include this in the warning signs
7) A correct earth connection is fundamental in order to guarantee
the electrical safety of the machine
8) Before carrying out any cleaning or maintenance operations make sure the power
is disconnected at the mains, the motor power cables are disconnected and the
batteries have been disconnected.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
- Mains power supply
230 Vac
.
-
Motor powered with a maximum voltage of
35 Vdc
.
- Upper cover in highly resistant shock-proof plastic.
- Integrated lower cover in die cast aluminium containing a never ending
screw and double reduction lubricated with permanently fluid grease.
- Irreversible reduction system with a key operated manual release mechanism.
- The incorporated electronic programmer contains the power stage, the logic
control, battery charger and the radio receiver decoding module. The power
supply is routed to the electronics card via a separate transformer which is
housed in the same container and is connected to the card by Faston clips.
- The system is fitted with electronic deceleration control which reduces the
stress caused by the gate inertia when it stops.
Accessories
106/CRENY
- Rack (
20 mm x 30 mm
) in glass fibre with upper
fastening slits (
1 m
).
106/CRENY1
- Rack (
20 mm x 30 mm
) in glass fibre with lower
fastening slits (
1 m
).
106/SLOAC
- Rack in galvanised steel (
22 mm x 22 mm
)
2 m
to be welded.
106/SLOAC2
- Rack in galvanised steel (
12 mm x 30 mm
)
1 m
with fastening slits.
950/XLBS
- Contact safety edge available in lengths of:
1,5
and
3,0 m
maximum height
70 mm
.
Attention!
Only for EU customers -
WEEE marking
.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differen-
tial collection site for electronic and electrical goods or to send
it back to the manufacturer if the intention is to replace it with a
new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and will
be dealt with according to the laws and standards of the individual member
nation.
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger.
During blackouts with a flat battery the gate can be released and manually
manoeuvred using the supplied release key (see manual release fig. 8).
Periodically check the moving parts for wear and tear and grease if required,
using lubricants which maintain their friction levels unaltered throughout time
and are suitable for temperatures of
-20 to +70°C
.
Eventual repair work must be carried out by specialised personnel using
original spare parts.
The appliance is not suitable for continuous operation and may only be oper-
ated using a duty cycle of
70%
.
Before starting the installation make sure that the structure which is to be
automated is in good working order and respects the local standards and
regulations in force. To this end ensure that:
4HESURFACEOFTHESLIDINGGATE
A
ISSMOOTHANDHASNOPROTRUSIONSUPTO
a distance of
2.5 m
from ground level.
Protrusions on the gate surface which are not greater than
3 mm
and have
rounded edges are acceptable.
If the surface of the gate is not smooth, the entire height up to
2.5 m
from
the ground must be protected by two of the following devices:
a) photoelectric cells
b) contact safety buffer
THEDISTANCE
B
BETWEENTHElXEDPARTSANDSLIDINGPARTSOFTHEINSTALLATION
must not exceed
15 mm
.
THE RUNNER GUIDE
C
PREFERABLY ROUND SHOULD BE SECURELY lXED TO THE
ground, completely exposed and free of any imperfections which could
inhibit the correct movement of the gate.
- when the gate is closed a space of
50 mm
D
MUSTREMAINFORTHEENTIRE
HEIGHTOFTHEFRONTPARTOFTHEGATEANDAMECHANICALTRAVELLIMIT
E
MUST
be positioned on the upper part of the gate.
4HEFREESPACE
D
CANBECOVEREDWITHARUBBERANTICRUSHBUFFER
F
OR
better still a pneumatic or photoelectric contact safety buffer.
IFTHEGATESLIDESPASTAlXEDSTRUCTURE
G
WHICHHASRAILINGSORBARSLEAVING
open spaces, it must be protected in one of the following ways:
DISTANCE
H
GREATERTHAN
500 mm
: no protection required;
DISTANCE
H
BETWEEN
500
and
300 mm
WIREMESHFENCING
I
ORPUNCHED
METALPLATING
L
WITHANOPENINGWHICHDOESNOTALLOWTHEPASSAGEOFA
25 mm
DIAMETERSPHERE
M
MUSTBElTTED
DISTANCE
H
SMALLERTHAN
300 mm
WIREMESHFENCING
I
ORPUNCHEDMETAL
PLATING
L
WITHANOPENINGWHICHDOESNOTALLOWTHEPASSAGEOFA
12 mm
DIAMETERSPHERE
M
MUSTBElTTED
4HEWIRESOFTHEMESH
I
MUSTNOTHAVEACROSSSECTIONOFLESSTHAN
2.5 mm
2
ANDTHEPUNCHEDMETALPLATING
L
MUSTNOTHAVEATHICKNESSOFLESSTHAN
1.2 mm
0ROTECTIONISNOTNECESSARYFORTHEAREA
P
IFTHElXEDSTRUCTURE
with railings or bars is over
2.5 m
above the ground.
IMPORTANT REMARKS
IMPORTANT REMARKS
IMPORTANT REMARKS
IMPORTANT SAFETY INSTRUCTIONS
Q
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
WARNING
PRELIMINARY CHECKS (fig. 1, pag. 2)
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICU-
LAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
. NOT READING THESE IMPORTANT
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM AND CREATE DANGER
SITUATIONS FOR THE USERS OF THE SYSTEM.
USER INSTRUCTIONS
Summary of Contents for 100/SL324EBSB
Page 50: ...NOTES 50...