19
The segments regarding the command status
(LED “ON”
command active) and safety status
,%$h/.vSAFETYDEVICEATR
est) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once
999999
has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the
test
mode (only activated when the motor
has stopped) it is possible to check the status of
the command and safety devices and carry out
eventual controls. The warning lights will activate
once, each time a “
TA-TC-TAL-TD-TB-
FTCI-CSP
” command is received. In this mode
you can activate serial line communication by
using the external program, which is to be
connected to the
CSER
connection via cable (fig.
3). While communication is active dashes will
appear on the display; after 5 seconds of inactivity
you will be moved back to the
TEST
mode. To
return to the normal operating mode press the
“test” command again and wait for 10 seconds.
PRESS PROG
Memorising the DIP-SWITCH settings and
displaying the firmware version (e.g. “
V10
”)
PRESS PROG
PRESS PROG
10 sec
When the
TA-TC-TD-TAL-TB-FTCI-FTCS
inputs are activated the warning lights will light up.
PRESS PROG
The status of the security devices
TB
,
FTCi
and
CSP
are always shown on the display.
PRESS
PROG
Each time
PROG
is pressed
the limited opening distance,
measured in metres, will
increase (from 1 to 9).
Limited opening setting from 1 to 9 metres (in the
example it has been set to 3 metres).
10 sec
10 sec
PRESS PROG
Connect the
programming device
(
CSER
) and activate it.
5 sec
10 sec
PRESS PROG
Setting the current sensor.
MOTORCONSUMPTIONAMP
MOTORCONSUMPTIONAMPS
MAXIMUMTOR
que ( max. 9 amps )
PRESS PROG
Each time
PROG
is pressed
the number will increase (from 1
to 3).
10 seconds after the last
modification you will be automatically
moved out of the mode and the
selected values will be saved (eg. 2)
10 seconds after the last
modification you will be
automatically moved out of
the mode and the selected
values will be saved (eg. 4)
PRESS PROG
10 sec
10 sec
10 sec
DISPLAY MODE
Automatic repositioning
If the programmer blocks due to an encoder count error
or after a
programmer reset
, the warning lights and indicator light will flash simul-
taneously for
2 seconds
and will then switch off for
10 seconds
.
After the programmer has been in this condition for
3 minutes
it will (after
pre-flashing for
10 seconds
) automatically move the gate, slowly, to the
completely closed position (2 times as in the programming procedure) in
order to recover the correct position.
At this point the programmer will function normally.
To carry out automatic repositioning without waiting for
3 minutes
you may
send a (
TA, TC, TAL
or
TD
) command to the programmer.
No commands will be accepted during repositioning but the security devices
will cut in and block all movement if they go into alarm.
s4OINTERRUPTTHEREPOSITIONINGMANOEUVREANDDELAYITFORANOTHER
3 minutes
,
PRESSTHE
PROG
BUTTON
Using the
PROG
button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
ACCESSTHE
test
MODE
- set the limited opening distance;
- setting the current sensor level
.