8200-M628-O1 Rev A
212G/212GX Installation & Technical
Page 35
SETUP AND CALIBRATION, Cont
If SMA is selected, the data will be transmitted in the following format:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
lf =
Line Feed
s =
Flags
Z= center of Zero, O = Overcap, E = zero Error,
e = weight not currently being displayed
r =
Range
1, 2, 3, ...
n =
Mode
G = Gross, T = Tare, N = Net
m =
Motion
M = Motion, " "(
blank
) = no motion
f =
Custom
Custom flag
xxxxxx.xxx = Weight
Six digits with decimal point
uuu =
Units
ton, lb , l/o, oz , t , kg , g
cr =
Carriage Return
(hex 0D)
If SB-400
*
or Computer is selected, the data will be transmitted in the following format:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s =
Sign
"-" = negative, " " (
blank
) = positive
xxxxxx.xxx = Weight
Six digits
d =
Decimal point
Added to string if enabled in setup
uu =
Units
tn, lb, l/o, oz, t, kg, g
m =
Mode
G = Gross, N = Net
cc =
Weight Status
OC = overcap
CZ = center of zero
MO = motion
ee = weight not currently being displayed
cr =
Carriage Return
(hex 0D)
*
The SB-80, SB-300 (
multiple displays not supported
) and WinVRS use the SB-400 format.
If SB-200 is selected, the data will be transmitted in the following format:
<cr><s><xxxxxx><d><c><uu><m> ETX
Where:
cr =
Carriage Return
(hex 0D)
s =
Sign
"-" = negative, " " (
blank
) = positive
xxxxxx.xxx = Weight
(with leading zeros)
d =
Decimal point
Embedded into weight (after weight dpp
=NO
)
c =
status
m = motion
o = overcap
e = weight not currently being displayed
uu =
Units
tn, lb, l/o, oz, t, kg, g
m =
Mode
G = Gross, N = Net
ETX =
End of TeXt
(hex 03) MUST terminate ALL serial commands
If Rice Lake IQ355 is selected, the data will be transmitted in the following format:
<stx><s>xxxxxxx<u><m><s><cr><lf>
If AnDFV is selected, the data will be transmitted in the following format:
<hdr1>,xxxxx<uu><cr><lf>
Summary of Contents for 212G
Page 2: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 2 ...
Page 10: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 6 INSTALLATION CONT Figure No 2 ...
Page 27: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 23 Lamp test on power up ...
Page 52: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 48 ...