8200-M628-O1 Rev A
212G/212GX Installation & Technical
Page 40
SETUP REVIEW
The 212G/212GX indicators allow several operational parameters to be reviewed and changed
without breaking the calibration seal. These operational parameters are:
Power Up Zero Reset Enable/Disable
Time
Format
Digital Output Control Enable/Disable
Sleep Mode Feature Enable/Disable
Auto Shutoff Feature Enable/Disable
Serial Input / Output Configuration
Baud
Rate
Parity
Number of Data Bits
Number
of
Stop
Bits
Continuous Output Port 1
Continuous
Output
Format
Continuous Output Port 2
Continuous
Output
Format
Print
Tab
Settings
Printer Port Selection
Time
Date
Consecutive
Number
Gross
Weight
Tare
Weight
Net
Weight
Gross Weight Accumulator
Net
Weight
Accumulator
Count
Piece
Weight
To enable the Setup Review feature, with the indicator ON:
1. Press the
*
key. The indicator will respond by showing the
FunCt=
(Function) prompt
and alternately flashing off and on (all ON, weighing unit off, then all OFF, weighing unit
ON) the annunciator display.
2. Press the
ZERO/REVIEW
key. The display will change to the prompt for the selection of
power-up zeroing (
PUO=
).
3. Using the same procedure as described in the Setup and Calibration section of this
manual, make the required changes.
4. Press the
*
key to return to the previous prompt.
5. To exit Setup Review, press the
ENTER
key to step through the remaining prompts OR
at anytime, cycle the power (press the
ON/OFF
key twice).
Summary of Contents for 212G
Page 2: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 2 ...
Page 10: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 6 INSTALLATION CONT Figure No 2 ...
Page 27: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 23 Lamp test on power up ...
Page 52: ...8200 M628 O1 Rev A 212G 212GX Installation Technical Page 48 ...