8527-0544-2M Rev B
APS Enterprise Scale
7
SETUP AND CONFIGURATION
The keypad of the Enterprise has two keys, ZERO and UNITS which have the following
functionality when in setup mode:
ZERO – When a prompt is currently being shown (not the value of the prompt), pressing the
ZERO key will skip to the next prompt. If the value of a prompt is being shown,
pressing the ZERO key will toggle between the acceptable values for the current
prompt.
UNITS – When a prompt is currently being shown (not the value of the prompt), pressing the
UNITS key will display the value for that prompt. If the value of a prompt is being
shown, then pressing the UNITS key will save the current value and advance to
the next setup prompt.
To Enter Setup
1. Remove the Calibration Switch Access screw located
on the bottom of the scale.
2. With the scale ON, use a 1/8” or 3 mm Hex Key
Wrench or other small tool and press the Calibration
Switch.
3. The display will change to show
type
.
Type
(Scale Type)
This will determine the capacity, interval, decimal, and converted units (if applicable).
Press the UNITS key to show current setting. If value displayed is acceptable, press the
UNITS key again to save it. Otherwise, press the ZERO key to step through selections for a
new value and then press the UNITS key to save it. The following types are selectable for
the Enterprise scale:
10
= APS10
30 lb x 0.01 lb (15 kg x 0.005 kg)
15
= APS15
15 lb x 0.01 lb (7.5 kg x 0.005 kg)
30
= APS30
30 lb x 0.01 lb (15 kg x 0.005 kg)
70
= APS70
70 lb x 0.02 lb (31 kg x 0.01 kg)
150
= APS150
150 lb x 0.05 lb (60 kg x 0.02 kg)
160
= APS160
160 oz x 0.1 oz
250
= APS250
250 lb x 0.1 lb (125 kg x 0.05 kg)
TEST
FACTORY TEST SETTINGS
UnS
(Motion Range)
This is the motion range of the scale, or the number of divisions that the scale weight can
change without setting the motion indicator.
Press the UNITS key to show current setting. If value displayed is acceptable, press the
UNITS key again to save it. Otherwise, press the ZERO key to step through selections for
a new value and then press the UNITS key to save it.
Allowable values are 0 through 9.
Calibration Switch Access