background image

DIGITAL PHYSICIAN 

Waist-High Scale 

Model 8430 Series 

Operating Instructions 

CARDINAL SCALE MFG. CO. 

8525-M041-O1 Rev K 

PO BOX 151 

x

WEBB CITY, MO 64870

Printed in USA

10/12

PH (417) 673-4631 

x

FAX (417) 673-5001 

www.detectoscale.com  

Technical Support: Ph: 866-254-8261 

x

 techsupport@cardet.com 

This Document is Hosted by: www.oldwillknottscales.com

Summary of Contents for Detecto 8430 Series

Page 1: ...uctions CARDINAL SCALE MFG CO 8525 M041 O1 Rev K PO BOX 151 x WEBB CITY MO 64870 Printed in USA 10 12 PH 417 673 4631 x FAX 417 673 5001 www detectoscale com Technical Support Ph 866 254 8261 x techsupport cardet com This Document is Hosted by www oldwillknottscales com ...

Page 2: ......

Page 3: ...ned herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of application however success and safety in working with tools depend to a great exte...

Page 4: ...ck washers securing the indicator bracket to the column 4 Lower load cell and draft rod assembly into column Draft Rod must pass through opening in column bracket Referring to Figure No 1 make sure open end of lower draft rod hook is facing forward toward platform 5 Next referring to Figure No 3 fasten top hook bolt of load cell assembly C to column Make sure the load cell assembly does not touch ...

Page 5: ... CONT Figure No 2 10 32 Screw Lock Washer Indicator Bracket Figure No 3 Figure No 4 Grommet Load Cell Cable Raise Draft Rod Push Lever Column Bracket Opening Draft Rod Figure No 1 Column C 8525 M041 O1 Rev K x 8430 Series 3 ...

Page 6: ...connected to scale press PRINT ENTER key to print a ticket 5 Remove patient from scale Zero Weight Display 1 In Gross Weight mode GROSS annunciator on press ZERO key 2 Weight display will return to zero ZERO and STABLE annunciators will turn on to show a stable center of zero gross weight condition Metric Conversion Press UNITS key to toggle between pounds and kilograms Note that the lb or kg annu...

Page 7: ...is ready for use 3 Perform tare operation if required Refer to Push Button Tare or Tare Weight Entry in previous section for instructions on using tare 4 Place patient on the scale and then press ID HEIGHT key 5 If Feet Inches were selected in setup for height measurement display will change to show FEEt a Use numeric keys to enter 1 digit for height in feet then press PRINT ENTER key b Display wi...

Page 8: ...it for height in feet and then press PRINT ENTER key b Display will change to show inCH c Using numeric keys enter up to 3 digits for height in inches and then press PRINT ENTER key or press PRINT ENTER key if no inches are required 10 If Centimeters was selected in setup for height measurement display will change to show Cn _ a Using numeric keys enter up to 4 digits for height in centimeters and...

Page 9: ...ion instructions Height Rod Installation 29 47 64 5 15 64 9 64 diameter holes 1 from center of column to center of hole IMPORTANT Measure from bottom of column not floor or scale base 2 1 Remove the height rod height rod brackets and hardware pack from the cardboard insert 2 Attach the height rod brackets to the height rod using the four screws lock washers and nuts enclosed in the hardware pack T...

Page 10: ...e four hex head screws on the back of the column 4 Pull down to set the screws in the small end of the slotted hole and secure the bracket to the column 5 Use the included wrench to tighten the hex head screws Do not over tighten the screws Height Rod Bracket Scale Column 8525 M041 O1 Rev K x 8430 Series 8 ...

Page 11: ...poon rests horizontally upon the top of the person s head t aise 4 Read the height of the person as follows x If the back of the spoon points to the outer height rod then it points to the correct height x If the back of the spoon points to the inner height rod then the correct height is read at the top of the outer height rod see Read arrow on the outer height rod 5 While holding the spoon horizon...

Page 12: ...crews in the back of the column Screws and wheel bracket 2 Place the wheel bracket against the back of the column and align the holes in the bracket with the holes in the column 3 Install the two screws removed in step 1 securing the wheel bracket to the column 8525 M041 O1 Rev K x 8430 Series 10 ...

Page 13: ...ts Soft water is much gentler on the painted steel s surface 3 Avoid the use of acetone thinner or other volatile solvents and abrasive type cleaners for cleaning If required a mild solvent such as mineral spirits can be used to remove oil grease tars wax and similar substances Use a cloth dampened with mineral spirits and apply only to areas that are contaminated Follow up the use of this mild so...

Page 14: ...4 SCW HEX HEAD 1 4 20 X 3 4 1 6007 0013 SCW BLT HEX HD 1 4 20x3 4 SS 11 1 6024 0003 WASHER FLAT 9 32 ID X 5 8 OD 1 6024 0037 WASHER LOCK HELICAL SP 10 REG SS 12 1 0033 B104 0A TOP PLATE ASSY 13 1 593R986 SERIAL TAG 14 2 6024 0049 WASHER LOCK EXT 10 15 6 6024 0047 WASHER LOCK EXT TOOTH 1 4 TYPE A Z PL 16 6 6021 1423 SCW TRUSS HEAD MACHINE SCW 1 4 20 X 1 2 17 2 6021 1045 SCW HEX HEAD 10 32 X 1 2 Z P...

Page 15: ...PARTS IDENTIFICATION CONT FINAL ASSEMBLY CONT 8525 M041 O1 Rev K x 8430 Series 13 ...

Page 16: ... BASE ASSY S S FOR 8430S 8431S 8437S 4 2 3P60 CHECK PLATE 5 2 6021 0985 HEX WASHER HD SCW 10 X 1 2 6 4 63K1038 BASE LEG 7 1 2U58 UNION CENTER HANGER 8 1 3P8003X SHORT LEVER ASSEMBLY 9 4 3P8059 UNION HANGER 10 1 3P122 BUMPER 11 1 3P8002X LONG LEVER ASSEMBLY 15 6 6024 0047 WASHER LOCK EXT 1 4 16 6 6021 1423 SCW TRUSS HEAD 1 4 20 X 1 2 8525 M041 O1 Rev K x 8430 Series 14 ...

Page 17: ...PARTS IDENTIFICATION CONT BASE ASSEMBLY CONT 8525 M041 O1 Rev K x 8430 Series 15 ...

Page 18: ...ob site This limited warranty honors only labor performed by Detecto authorized dealers This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not include replacement of expendable or consumable parts This does not apply to any item which has deteriorated or damaged due to wear accid...

Page 19: ...duct Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or contract Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured The foregoing is in lieu of all other warranties exp...

Page 20: ...8525 M041 O1 Rev K x 8430 Series 1 8525 M041 O1 Rev K x 8430 Series 8 1 ...

Reviews: