background image

 

5

CONFIGURATION 

 
The Scale has been pre-configured at the factory and should not require configuration for use in 
most applications.  In the event that the factory settings do not meet the requirements of your 
application, the following describes the steps to configure the scale. 
 
TO BEGIN CONFIGURATION: 

1. Press the ON/OFF key to turn on the scale. 

2.  Press and hold the SET key for 3 seconds.  When the display shows   

Set

 , release the 

SET key to enter the Configuration mode.  The display will change to show   

Unit

 . 

 

WEIGHING UNITS 

To select “lb/oz” (pounds/ounce) weighing units (10 lb x 0.1 oz): 

1.  With the display showing  

Unit

 , press the SET key.  The display will change to show 

g

” and the status (  

On

  or  

OFF

 ). 

2. Press the UNIT key to toggle between: 

Enable (display will change to  

On

 ) or  

Disable (display will change to  

OFF

 ). 

3. Press the SET key. 
4.  Repeat above steps for each weighing unit mode :  

•  g = grams (5000g x 1 g)  
•  lb oz = pound ounces (10 lb x 0.1 oz) 
•  lb oz 1/8 = pound / 1/8 ounces (10 lb x 1/8 oz) 
•  lb = pounds only (10 lb x 0.005 lb) 
•  oz = ounces (160 oz x 0.05 oz) 
•  oz 1/8 = 1/8 ounces (160 oz x 1/8 oz)  

5. The display will return to 

UNIT

 . 

6. Press UNIT key to proceed to AUTOMATIC SHUTOFF 

 

AUTOMATIC SHUTOFF 

 
1.  The display will change to AOFF . 
2. Press the SET key to begin selection of the automatic shut-off time (in seconds).   
3. Press the UNIT key to toggle through the selections, 

120

180

240

300

, or 

OFF

4.  When the desired time or Off is displayed, press the SET key.   
5.  The display will return to 

AOFF

 . 

6. Press UNIT key to proceed to GRAVITY COMPENSATION. 

 

Summary of Contents for Detecto MARINER WPS10

Page 1: ...OOF DIGITAL PORTION SCALE OWNER S MANUAL CARDINAL SCALE MFG CO 8528 M405 O1 Rev A PO BOX 151 WEBB CITY MO 64870 07 13 PH 417 673 4631 FAX 417 673 5001 www detectoscale com Technical Support Ph 866 254 8261 techsupport cardet com ...

Page 2: ......

Page 3: ...ontained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of application however success and safety in working with tools depend to a great...

Page 4: ...2 ...

Page 5: ...ck on the side of the scale and then plug power supply into the proper electrical outlet The scale is now ready for operation BATTERY PACK The scale uses a 4 8 VDC 1800 mA built in rechargeable battery pack The WPS10 can operate for up to 80 hours of continuous use with a fully charged battery pack BATTERY CHARGING To recharge the battery pack the power supply must be connected to an AC power outl...

Page 6: ...e displayed weight is in pounds oz The oz annunciator is turned on to indicate that the displayed weight is in ounces lb oz Both the lb and oz annunciators are turned on to indicate that the displayed weight is in pounds and ounces g The g annunciator is turned on to indicate that the displayed weight is in grams The low battery annunciator is used with the battery operation It will turn on to ind...

Page 7: ...rement if selected during configuration of the scale 2 Press and hold three 3 seconds to turn display back light on or off TARE 1 Press to reset the displayed weight to zero up to 100 of the scale capacity ON OFF 1 Press and release to turn on scale 2 Press and release to turn the scale off ...

Page 8: ...ts press TARE before adding each ingredient 5 To display the total weight of ingredients press the SET and TARE keys at the same time 6 Note that upon removing the container and ingredients the scale will display a negative weight Press the TARE key to return the scale to zero HIGH LOW WEIGHT CHECKING The scale may be set to alert you when either over or under a set limit 1 Press and hold the TARE...

Page 9: ...nge to show g and the status On or OFF 2 Press the UNIT key to toggle between Enable display will change to On or Disable display will change to OFF 3 Press the SET key 4 Repeat above steps for each weighing unit mode g grams 5000g x 1 g lb oz pound ounces 10 lb x 0 1 oz lb oz 1 8 pound 1 8 ounces 10 lb x 1 8 oz lb pounds only 10 lb x 0 005 lb oz ounces 160 oz x 0 05 oz oz 1 8 1 8 ounces 160 oz x ...

Page 10: ...97 for the Gravity Compensation If the GrAu is disabled the scale will use the value obtained from the factory Tech Support and entered by the operator for the Gravity Compensation To change the Gravity Compensation value 1 Press and hold the UNIT key while pressing the ON OFF key to turn on the scale and enter Gravity Compensation mode the display will show 9 797 or the current value 2 Press the ...

Page 11: ...mes DO NOT place scale in front of heating cooling vents DO clean the scale with a damp soft cloth and mild non abrasive detergent DO clean the scale by submerging in dishpan and using mild non abrasive detergent NOTE Before submerging scale in dishpan make sure power jack cover on side of scale is completely inserted battery pack cover on bottom of scale is installed and water temperature does no...

Page 12: ...8 ...

Reviews: