12. Warranty 

 

12.1 Scope 

 

This CuroCell

® 

system is covered by a 2-year warranty for manufacturing defects. The warranty 

does not apply to normal wear and tear or damage due to negligence or improper 

handling/care. 

 

12.2 Service and maintenance 

 

The

 

CuroCell

®

 alternating pressure mattress is a medical device, in accordance with Medical 

Device Regulation MDR (2017/745), that is used to prevent and help treat pressure 

ulcers/pressure injuries. For this reason, we recommend that the pump is regularly serviced 

and inspected to maintain functionality and performance. Like other technical devices, a pump 

that is properly cared for works better and lasts longer.  

 

 

Service and maintenance must always be performed by Care of Sweden or one of its 

authorised service providers. Only use spare parts that have been approved by Care of 

Sweden. The use of non-approved spare parts invalidates the warranty. 

 

Faults and defects regarded as warranty faults are rectified free of charge. 

 

A warranty claim must be submitted to Care of Sweden before the product is returned. 

 

12.3 Recommended life time of the product 

 

 

This product’s expected life time is estimated to be 5 years. 

 

 

13. Other information 

 

13.1 Disassembly and recycling 

 

 

Except for certain parts of the pumps, energy recovery is possible for almost all material in 

CuroCell

®

 products through incineration at waste incineration facilities.  

 

Pump:

 

A used CuroCell

®

 pump must not be disassembled. Instead it should be taken to a recycling 

centre. The product is sorted as “electronic waste”. 

 

Mattress:

 

A used CuroCell

®

 mattress must be taken to a recycling centre. The product is sorted as 

“combustible waste”. Care of Sweden complies with its manufacturer responsibility through its 

affiliation with the REPA register and El-kretsen AB. For more information, please contact Care 

of Sweden. 

 

13.2 Returns and warranty claims 

 

 

Contact Care of Sweden 

before 

returning the product. The return postage will be paid by Care 

of Sweden if the fault is covered by the product warranty, otherwise by the customer. 

 

 

Summary of Contents for CuroCell AUTO4

Page 1: ...Instructions for use 2020 12 08 CuroCell AUTO4 CuroCell AUTO4 CX13 Automatic active air mattress systems Instructions for use item number 95 001616...

Page 2: ...duct description 6 3 Assembly Installation 9 4 Operation 10 5 Reuse cleaning and reconditioning 13 6 Storage 15 7 Maintenance 15 8 Troubleshooting 16 9 Technical description 17 10 Spare parts 19 11 Op...

Page 3: ...functionality by performing a hand check see section 4 4 4 When the product is used for individuals needing special supervision such as children continuous monitoring is required 5 The mattress is pro...

Page 4: ...least 1 meter from the control unit 15 Never use the product if the power cable plug of the control unit or power supply housing is defective if the control unit housing is damaged or if it is not fun...

Page 5: ...authorities regarding medical devices the manufacturer is required to report all accidents or incidents involving the products We would be very grateful for all information involving accidents or inc...

Page 6: ...information on the last page 2 Product description 2 1 Mattress 1 Mattress 2 CPR Rapid deflation 3 Pump connector 4 Pump NOTE For certain users such as amputees the recommended height measurement may...

Page 7: ...automatically sets the pressure based on the user s weight posture and position There are three ways to use this function 1 The system adjusts the settings automatically when the system has been start...

Page 8: ...is inflated and provides firm support This function automatically reverts to the previous setting after about 24 minutes NOTE The automatic settings are overridden when using this programme 5 Panel l...

Page 9: ...y to the moving parts of the bed Check the cells and press studs to ensure they are correctly assembled 2 Hang the pump on the foot end of the bed or place the pump on a firm level surface Place the p...

Page 10: ...4 2 Programme selection Four different programmes are available See section 2 3 for detailed information We recommend Alternating mode as the default setting 4 3 Comfort setting fine tuning The air p...

Page 11: ...pump control panel If the problem is not resolved within about five minutes the notification will be reactivated The pump is also equipped with a power supply notification If the pump loses power an a...

Page 12: ...for the user s heels This is achieved by disconnecting shutting down the cell in the mattress directly under the user s heel s It will no longer be inflated and will create a space between the cells...

Page 13: ...oes not affect the pump MATTRESS COVER Covers can be wiped off with a mild cleaning solu tion for this purpose such as alcohol with or with out tenside surfactants Isopropanol 70 oxidizing solutions c...

Page 14: ...ergent and or disinfectant 6 Put the mattress together If cells for any reason have become loose from the tubes these must be replaced according to the drawing in section 2 1 FOAM CORE Clean the affec...

Page 15: ...ubes or connectors are damaged or pinched Contact Care of Sweden or your local distributor if any spare parts are required 7 2 Changing fuses 1 Remove the plug from the wall socket when replacing fuse...

Page 16: ...sections 4 3 and 4 4 for more Mattress not stationary Check that the mattress is secured with the elasticated straps to the underlying mattress or if the mattress has an integrated foam cushion secure...

Page 17: ...NB Care of Sweden reserves the right to modify the product specification at any time 9 2 Standards The system is tested and approved according to the following European standards where applicable req...

Page 18: ...CE marked in accordance with Medical Device Regulation MDR 2017 745 Machine wash at 95 C Placed directly on the bed base Tumble dry Do not iron Recommended user weight User information category Wipe c...

Page 19: ...PU 80x13 cm CC 901002 K Air cell PU 85x13 cm CC 901003 K Air cell PU 90x13 cm CC 901004 K Air cell PU 105x13 cm CC 901005 K Air cell PU 120x13 cm CC 8217 Fuse 2 pack CC 400903 Pump for mattress width...

Page 20: ...4 105 120 cm AUTO4 CX13 Sheet holder each Only AUTO4 Item no CC 9075 Item no Description CC 900220 Heel function with valve 4 cells CC 900222 Heel function with valve 3 cells 11 3 Other accessories To...

Page 21: ...regarded as warranty faults are rectified free of charge A warranty claim must be submitted to Care of Sweden before the product is returned 12 3 Recommended life time of the product This product s ex...

Page 22: ...22 14 Notes...

Page 23: ...23...

Page 24: ...se Internet www careofsweden com Postal address Care of Sweden AB Box 146 SE 514 23 Tranemo SWEDEN Visiting address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Deliveries address Byns v g 4A SE 514 33 T...

Reviews: