Tip: When the nut is removed, the bolt will slide out of the arm mounting block inside the arm channel.
Placing tape on the head of the mounting bolt and the spacers will prevent the bolt and the spacers
from falling out when the nut and motor are removed.
10. Remove the rest of the motor assembly. The motor assembly consists of the motor, mounting frame,
gears, shaft and roller end cap.
11. Place the new motor assembly in position over the mounting bolt. Ensure that the spacer-washers are
all accounted for.
12. Secure using the washer and lock nut removed previously. The nut should be tightened until snug but
the motor head should be able to swivel by hand.
13. Attach the rear cover to the motor assembly using the large screw removed previously.
14. Attach the motor and cable wires to the terminals inside the rear cover.
15. Align the roll bar with the end cap on the motorized arm assembly.
Rotate the end cap until the slot
in the cap aligns with the empty slot in the roller assembly, and then press the roller assembly fully into
the cap. The end cap must seat squarely over the end of the roller assembly when complete.
NOTE:
On early units, a spider gear was inside the end cap to hold the roller tube in position with the
drive shaft. The replacement end cap no longer requires the use of the spider.
16. Secure the end cap to the roller assembly using two #10 x 5/8 square-drive screws.
17. Restore power and test operation. If the awning moves in the wrong direction (i.e. extends when retract
is pushed) reverse only the two motor wires in the rear cover.
18. Attach the front cover using the small screws removed previously.