E
CLIPSE
Service
Manual
Carefree of Colorado
18
052547-301r10
D07 A
WNING
D
OES
N
OT
M
OVE
W
HEN
K
EY
F
OB
B
UTTONS
A
RE
P
USHED
Before continuing, ensure that the system is working correctly at the switch panel. If not, go to DO1" The Awning
Does Not Extend and/or Retract Using the Extend/Retract Switch".
NOTE: For series I switches, the Mode switch must be in the POWER ON or AUTO-RETRACT ON positions for the
key FOB to work. For series III switches, the On/Off switch must be ON.
A
Remove battery from Key FOB and test. Should measure
between 2V-3V.
YES
Battery OK - Key FOB does not work
– go to test B
NO
Replace battery
B
Confirm that the Receiver is programmed for the Key FOB
(refer to page 28)
If system does not work; go to step C
C
Program a second Key FOB (refer to page 28) and test
YES
2nd Key FOB works. 1st Key FOB is
defective.
NO
2nd Key FOB does not work; go to
step D
D
Check the cable between the RR24 and Direct Response
control box. As a continuity check, Pin 1 of connector 1 goes
to Pin 1 of connector 2; pin 2 goes to pin 2; pin 3 goes to pin 3
and pin 4 goes to pin 4
YES
Cable is OK. Confirm that cable is
securely plugged in; go to step 4
NO
Repair or Replace as required.
D
Replace the RR24 Receiver and test
YES
System works OK. 1st receiver is
defective
NO
System does not work. Reinstall 1st
receiver; go to step E
E
Replace Auto-Retract control box
Summary of Contents for ECLIPSE 2015
Page 4: ......