background image

Carefree of Colorado  

Installation Manual 

Mirage 

 7 

052979-003r5 

C

ONTROL 

B

OX 

I

NSTALLATION

 

(refer to wiring diagram on page 9) 

NOTE: The control box is not rated for exterior 

installations and must be mounted in the 

INTERIOR

 

of the vehicle. 

1. 

After determining the location of the control box, remove 
the box lid. 

2.  Attach the box using a minimum of two (2) #8 x 3/4 

screws.  The screws should be mounted in opposite 
corners. 

3. 

Route a 2-conductor 14AWG NM wire w/ ground from the AC 
power source to the box.  It is recommended that the installer 
provide a dedicated AC circuit that is protected by an 
appropriate sized fuse/circuit breaker.  Each patio awning 
draws a maximum of 3 amps.  Connect wires to the control 
box as shown in the wiring diagram. 

4. 

Splice the awning motor wires to a 3-conductor 14AWG NM wire w/ ground. (Refer to note 1 on the 
wiring diagram on page 9.) 

5. 

Route the cable wire from the motor to the control box and attach the wires to the terminals as shown. 

NOTE:  For RH motor configurations: 

 

RED WIRE

 goes to terminal (1); 

BLACK WIRE

 goes to terminal (2). 

For LH motor configurations: 
 

RED WIRE

 goes to terminal (2); 

BLACK WIRE

 goes to terminal (1). 

6. 

Connect the cable from the switch panel to “ACC” in the control box. 

7. 

Connect the cable from the motion sensor to “AMD” in the control box. 

NOTE:  Use the slot cutouts in the box to route the phone cables. 

#8 x 3/4 Screw (2)

RTA0033a 

6 1/2” 

(typ) 

2 3/8” 

 

Figure 9.  Control Box. 

Summary of Contents for MIRAGE

Page 1: ...Plate Attachment Method 4 Mounting the Awning Unit 5 Securing the Awning 5 Electrical Installation 6 Important Notices 6 Switch Installation 6 Control Box Installation 7 Installing the RF Remote Receiver 8 Programming the Receiver 8 Operational Notes 8 Ignition Lockout Sensor Installation Optional 9 Wiring Diagram Direct Response System 10 Testing the System 11 Standard System Adjustments 12 Manua...

Page 2: ...translation of this document in whole or part is strictly prohibited without prior written approval from Carefree of Colorado SAFETY INFORMATION WARNING A WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION THAT IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY AND OR MAJOR PROPERTY DAMAGE CAUTION A CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION THAT MAY CAUSE MINOR TO MODERATE PERSONAL ...

Page 3: ...the Direct Response system Two configurations of the Mirage awning are available a RH passenger side and a LH driver s side The motor is located to the front of the awning reducing wiring to keep the awning controls to the front of the vehicle In the Wiring Diagram the RH configuration is shown detail A shows the alterations for the LH configuration Mirage Patio Awning Specifications The following...

Page 4: ... 133mm 1 2 3 8 Owner s Manual 1 3 9 Control Box 1 10 Screw Pan Head 8 x 3 4 4 11 Switch Plate 1 4 12 Switch Assy 1 4 13 Switch Mount 1 14 Cable 60 1 15 RF Receiver 433MHz 1 16 Screw Phillips Truss Head 6 x 1 2 2 17 Cable 60 1 18 Remote Control Key FOB 433MHz 1 5 19 Sensor Ignition Lock Out 1 20 Splitter 1 21 Cable 60 2 Notes 1 Specific awning configuration is specified at time of order including t...

Page 5: ...zed fuse circuit breaker Each patio awning draws a maximum of 3 amps MOUNTING PLATE LAYOUT AND INSTALLATION 1 Determine the location of the awning Mounting area must be plumb and clear of obstacles The mounting plate is 9 shorter than the awning w standard end caps 6 shorter than the back plate Reference Figure 1 The awning is factory set with minimum pitch Mounting height above a door opening or ...

Page 6: ...an 11 32 pilot hole into the structure Attach the plate using a 3 8 16 x 1 1 2 thread cutting screw 10 Confirm position of plate and repeat step 6 on the opposite end of the mounting plate 11 Continue to drill and attach using the 3 8 16 x 1 1 2 thread cutting screws until all mounting holes are done 12 For motorized configurations Drill one 1 1 2 hole through outer wall as shown in Figure 4 RH co...

Page 7: ...5 16 1 4 x 1 1 2 Lag Screw 3 plcs MIRAGE010 Figure 7 Securing the Awning 1 Adjust the awning horizontally as required 2 Open the awning approximately 3 feet to access the back panel of the awning case 3 Drill three 3 3 16 holes through the case mounting plate and into wall do not go through interior surfaces of wall in the approximate areas shown above 4 Ream out the holes in the case only to 5 16...

Page 8: ...installed An RF remote control is provided with the Direct Response system An optional ignition lockout is available The switches use a 5VDC signal to operate the control box eliminating the need for a junction box for the control panel Components are connected using terminated cables Terminated cable is 4 wire RJ11 terminated phone cord straight no twist This does not include 110VAC power connect...

Page 9: ...sized fuse circuit breaker Each patio awning draws a maximum of 3 amps Connect wires to the control box as shown in the wiring diagram 4 Splice the awning motor wires to a 3 conductor 14AWG NM wire w ground Refer to note 1 on the wiring diagram on page 9 5 Route the cable wire from the motor to the control box and attach the wires to the terminals as shown NOTE For RH motor configurations RED WIRE...

Page 10: ...ode when the red light comes on 3 Press and release the stop button on the remote The red light will go out after the receiver learns the remote signal NOTE Pressing the stop button will cause the blue up arrow button to default as the close retract function If a function button is pressed to train the receiver it will be programmed as the close retract button Example Pressing the bottom button wi...

Page 11: ...wning Applications 4 1 Disconnect the remote receiver cable from the EYE port in the control box Do not disconnect the cable from the receiver box 4 2 Connect the supplied 6 cable to EYE port in the control box 4 3 Attach the splitter to the other end of the cable 4 4 Plug the cable from the remote receiver into the splitter 4 5 Attach the Lock Out Sensor to the end of the 60 cable Route the cable...

Page 12: ...hes past the point of entry NOTES 4 Wires for the Ignition Lock Out Sensor are not pin specific 5 Splitter is used only when Optional Lock Out Sensor is installed Connect RF Receiver directly to EYE if Lock Out is not installed Detail A For LH Configuration Reverse Red Black Wires RED WHT BLK GRN grn wht blk RH Motor Wire Shown See Detail A for LH Motor For early units Label DSK was ACC Label EYE ...

Page 13: ...he 110VAC power 3 Press the POWER ON Press the EXTEND button the LED should illuminate while the awning extends and stay on after the awning auto stops Observe the awning it should fully extend The system performs an auto tension action when the awning is fully extended The awning rolls in reverse to tension the fabric The auto tension feature works only with the extend function when the awning is...

Page 14: ...S ADJUSTED IT IS IMPORTANT THAT THE LEAD RAIL IS PARALLEL TO THE AWNING HOUSING 1 Extend the awning fully 2 On one end loosen the 6mm hex screw located on the spring arm knuckle 3 SLIGHTLY loosen the 3 4 nut on the side of the knuckle 4 Turn the 3 4 adjustment nut located on the bottom of the knuckle CLOCKWISE raises the pitch COUNTERCLOCKWISE lowers the pitch NOTE When raising the pitch it is hel...

Page 15: ...NOTE During normal operation the awning will extend out then roll back slightly to tension the fabric 1 Extend the awning out completely 2 Confirm that the arms are fully extended The motor should stop and the fabric should be tight 3 If the motor continues to run the fabric will sag use a 4mm allen wrench to turn the OUT limit switch to DECREASE the motor run time 4 If the motor quits before the ...

Reviews: