63
ENG
Technical specifications
WTS LARGE +0300131IT rel. 1.0 - 05.09.2022
15. TECHNICAL SPECIFICATIONS
Technical data ROL (Reverse Osmosis Large)
ROL 160
ROL 320
ROL 460 ROL 600
ROL
1000
ROL 1200
Permeate production [l/h] *
160
320
460
600
1000
1200
Concentrate production [l/h]*
160
150
460
600
470
570
Circulation [l/h]*
160
150
460
600
450
450
Water consumption during operation [l/h]
320
470
920
1200
1470
1770
Max. Recovery rate [%]
50
68
50
68
Minimum water flow required for flushing [m3/h] – 2bar
0,9 - 1,2
1,8 - 2,1
Max. Working pressure [bar]
10
Feed water temperature [°C]
5 - 25
Feed water pressure [bar]
2 - 5
Feed water total dissolved salt [ppm]
< 750
Feed water conductivity [μS/cm]
< 1000
Number of membranes
2
4
2
2
4
4
Size of low-energy-membranes
2,5" x 40
4" x 40
4" x 40 XL
4" x 40
4" x 40 XL
Membrane pressure [bar]
7,9
8,8
7,4
7,9
8,1
8,8
Permeate pressure [bar]
2 - 4
Electrical connection
230V /1Ph /N /50 or 60Hz depending on product code
Electrical power [kW]
0,95
1,65
Weight (kg) during operation
75
83
100
125
Dimensions
height
1555
1550
[mm]
depth
510
700
width
940
1090
Permeate pipe connection
3/4" AG or John Guest Ø 15 mm
3/4" AG
Water connection
3/4" AG
Drainage connection
3/4" AG or John Guest Ø 15 mm
3/4" AG
Water hardness [°fH]
up to 50
Drain function
ü
Conductivity measurement
Permeate and feed water monitoring, alarm function included
* Specifications refer to the reference water quality: 15°C, TDS: 500 ppm, 26.7 °fH, permeat pressure: 1 bar
These values are theoretical because they can change with the temperature of the feed water and its chemical and
physical qualities. These values were used for feed water with a TDS of 500 ppm and a water temperature of 18°C.
The temperature of the feed water has a great influence on the productivity and quality of the permeate. As the
temperature increa- ses, the permeate output also increases, but with a worse conductivity value.
The recovery value is calculated as follows:
RECOVERY (%) = Permeate*
x 100
Permeate* + Concentrate*
* quantity
If a softening unit (e.g. the WaterLine-D) is connected upstream, the recovery value can increase up to 75%.
Summary of Contents for Large ROL 160-1K2
Page 2: ......
Page 6: ......
Page 43: ...43 ENG Control WTS LARGE 0300131IT rel 1 0 05 09 2022...
Page 59: ...59 ENG Spare parts WTS LARGE 0300131IT rel 1 0 05 09 2022 20 21 22 23 24 25 26 27 28 29 30...
Page 65: ...Notes...
Page 66: ...Notes...
Page 67: ......