INSTALLATION INSTRUCTIONS 

 

 

TROUBLESHOOTING 

 

Tranquility spa blowers have been designed for replacements on existing 
spas. For installation on a new spa, please contact us at 
sales@spablower.com or view our information on our website at 
spablower.com. 
For an existing spa, choose the correct blower per our website 
information. This data provides for the blower to operate correctly under 
all but the most extreme conditions. A blower must blow an adequate 
amount of air in order to keep itself cool. Over sizing a blower will cause 
the blower motor to overheat. Be sure to follow the correct procedures 
for sizing your blower.  See our website for proper sizing. 
Always refer to the spa manufacturer’s recommended operation 
documentation for the correct operation of your spa controller. 

Remove old blower. If there is any water present in the old 
blower, you MUST install a new check valve before installing a 
Tranquility blower. Warranty is void if blower is damaged by 
water intrusion. 

Connect the new blower to the air plumbing using the clamp 
provided. DO NOT GLUE TO THE BLOWER. The blower uses 
1-1/2” PVC pipe. You may require a reducing bushing if your 
blower plumbing is 2-inch. 

The Tranquility blower will make a louder than normal sound 
when water is first purged from the air injection plumbing. This is 
normal and the high noise will go away once the airline is clear 
of water and is putting air into the spa water. This “start-up” noise 
will occur each time the blower is started, as the water must be 
purged from a portion of the airline. 

The filters on the front of the Tranquility blower are washable. 
Keep these clean and free of dirt and other obstructions. Soapy 
water may be used to clean these filters. Be sure they are dry 
before reinstalling them.  Do not operate blower without the 
filters in place. 

  

TECHNICAL DATA 

 

 

 

 

Air Connection:  

1.5” PVC or 2” PVC (coupling not included) 

Maximum Ambient Temperature:  

55C (131F) 

Electrical

: 120 VAC Models or 240 VAC Models (240 Volt models are 60/50 HZ) 

Thermal Protection: 

Yes 

UL Insulation: 

Class B 

Mounting Orientation: 

Horizontal or Vertical (Air connection MUST be pointed 

down) 

Mounting: 

Three point mounting. Recommend installer use front mounting 

post and rear mounting for ease of installation. 

Symptom

 

Possible 

Cause

 

What to Do

 

No Power 

*Check main breaker. 
*Check sub-panel 
breaker. 
*Check GFCI circuit. 
*Be sure pump plug is 
plugged in fully to spa 
controller. 

Water/Moisture 
present in 
blower 

*Verify that blower is 
installed according to 
instructions. 
*Possible check valve 
failure. 

Thermal protector 
inside blower has 
tripped 

*Blower should reset in 
about 15 minutes. 
*Be sure air blower 
vents are free of debris. 

Damaged Cord 

*Turn off power. Cord 
must be factory 
replaced. Contact us. 

Blower will not 
operate 

Worn Motor 
brushes from 
regular usage 

*Replace Blower with 
new unit, brushes are 
not replaceable. 

Blower starts on its 
own 

Spa control began 
purge cycle 

*This is normal 
operation of the spa 
control. Refer to spa 
control manual 

Insufficient air 
coming into spa 

Blocked air jets or 
kinked air lines 

*Check airlines for 
kinks and proper 
connections. Clean 
blower air filters 

   