background image

___________________________________________________________________________ 

_____________________________________________ 

        By Carepeutic® 

16

 

With smart thermal control water temperature automatic balancing system. 

 

Calf-deep water container, water height about 18-20 cm.     

 

Infrared heated therapy function. 

 

Selective water temperature based on different needs.   

 

Equipped with detachable herbal bag container, one extra mineral stone container 
included.  

 

Smart design with LED indicator.   

 

Over-heat protection.    

 

Four selective automatic massage programs.   

 

Motorized rolling massage with four massage rollers.   

 

Motorized water drainage system with smart design, automatic lock or unlock system 
when draining. 

 

With built-in carrying handle.   

 

With hidden compartment for drainage and power cord storage.   

 

Built-in mobile wheels, easy for moving around and water drainage.   

 

Specifications:  

 

 

Default massage time: 50 minutes. 

 

Default water drainage time: 3 minutes. 

 

Default water temperature: 35°C/95°F (lowest) to 40°C/104°F (highest). 

 

The highest heating temperature: 48°C/117°F.   

 

The lowest heating temperature: 35°C/95°F. 

 

With 110V/60Hz UL power cord.   

 

Power consumption: 800W. (KH298) 

 

Luxury water container, big enough for any foot sizes. 

 

Cleaning and Maintenance 
 

 

Before cleaning, you must turn off the device and unplug the power cord from the 
electric outlet.   

 

Make sure the water drainage valve is closed and the power cord is properly stored 
inside the storage compartment. 

 

It is recommended to always drain out water along the water drainage valve; do not 
pour out water over the control panel. 

 

Clean the water container only with a soft cloth. Never use strong abrasives, 
detergents or cleaning agents for cleaning. 

 

Do NOT immerse the massager in water or under faucet to do cleaning. 

 

If you put in bath salt, herbal bag, or other spa detergents, try to clean up right after 
use to make sure the water valve is not blocked. To clean up, you can put in some 
clean water and turn on the massaging function for 1 minute and follow the water 
drainage procedure to drain out water.   

 

Storage 

Summary of Contents for KH298

Page 1: ..._______________ By Carepeutic Ozone Waterfall Foot and Leg Spa Bath Massager A Tradition for Foot Reflexology Instruction Manual Model KH298 This user manual provides both operation information of this product and its detailed specifications Read this manual and understand it thoroughly before operation ...

Page 2: ...have the gout arthritis joint deformation skin disease and allergic dermatitis have neurological disorder or perceptual disorder on skin have fractured or plastic surgery materials inside your knee joint legs or feet are unable to feel normal temperature we advise you to consult with your doctor before using this massager SAFETY NOTE Attention Never try to turn on the power or operate this device ...

Page 3: ...prohibited to have excited exercise should not use this device unless you have consulted with your doctor People with skin allergy wounded or after surgery and not well recovered should not use this device unless you have consulted with your doctor Unauthorized person is not allowed to reconstruct or replace the component of this device Do not use this device in sauna room or bath room or in area ...

Page 4: ...utlet 7 Use only the original adaptor that comes with the device 8 It is recommended not to use any electronic devices while using the foot spa massager avoid possibly dropping electronic devices into water container NOTICE this massager should not be used in the following cases Massage should be comfortable and pleasant Should pain or discomfort result discontinue use and consult your doctor Avoi...

Page 5: ...ore using this device if you have diabetes as diabetes can contribute to foot problems including decreased feeling or circulation to the feet If you take foot spa everyday you should rub lotion or skin moisturizer and wear socks for keeping warm after taking foot bath ATTENTION This device is being tested with water at factory if there is any water drops left inside water container it is normal To...

Page 6: ...___________________________________________ By Carepeutic 6 SPECIFICATIONS Default working time 50 minutes Default water drainage time 3 minutes Turn on the drainage function again if you need more time to drain out all water With 110V 60Hz power cord Power consumption 800W KH298 ...

Page 7: ...___________________________________________________________________________ _____________________________________________ By Carepeutic 7 PRODUCT PARTS Figure 1 Figure 2 ...

Page 8: ...___________________________________________________________________________ _____________________________________________ By Carepeutic 8 Figure 3 Figure 4 ...

Page 9: ..._________ _____________________________________________ By Carepeutic 9 Figure 5 water drainage OPERATION INSTRUCTION NOTE You must fill in water before turning on the foot bath massager Never try to operate this device without having water inside the water container ...

Page 10: ... Never try to operate this device without having water inside the water container Filling in water with water bucket Do NOT put your massager under faucet directly Be careful NOT to spill water onto the cover or control panel To save electricity or speed up water heating you can put in warm water but the warm water temperature should be less than 40 Celsius degrees Water Level refer to Figure 4 Wa...

Page 11: ...rature reaches 40 C When its water temperature cools down below 40 C the Heating function will be turned on automatically again and so on When the water temperature reaches its default maximum temperature 40 C the Keep Warm indicator light on LCD display will be on Figure 1 Note the Heating function will not be on if your fill in water temperature is already higher than its default maximum 40 C Ch...

Page 12: ...n on off massage function under P1 Figure 1 P1 Under P1 water temperature massage air bubble and ozone function can be chosen based on your need All buttons on the control panel are available for selection Under P1 if you do not change its default water temperature its water temperature will stay in between 35 C 95 F 40 C 104 F default setting P2 P3 P4 Preset spa programs Under P2 P3 P4 program ea...

Page 13: ... but not to disconnect the power cord from wall outlet The Drainage button on control panel cannot be used before the Drainage Switch is switched down at the back of case Figure 2 Drainage step by step procedures Put a water bucket under the water drainage valve Figure 5 Switch down the Drainage Switch at the back of case Figure 2 The water drainage valve will open Figure 5 At this time the LCD sc...

Page 14: ...terfall Switch to center position to have both waterfall and water jet function worked at the same time 14 Clean up Make sure your hands are not wet when unplugging power cord After each use before trying to clean up the container with dry towel always turn off power on control panel and unplug the power cord from wall outlet first Put power cord back to the storage compartment and have it closed ...

Page 15: ... Massage is Off and vise versa Ozone Preset NOT working Time Minute Preset 50 minutes Mode P4 Preset all functions are NOT selectable except Heating Temp Temp Heating Temp Temp Preset maximum heating temperature 43 Celsius Massage Preset when water temperature reaches 39C Massage is On all the time until you turn it off Air Bubble Preset when water temperature reaches 39C Air Bubble is On for 2 mi...

Page 16: ...time 3 minutes Default water temperature 35 C 95 F lowest to 40 C 104 F highest The highest heating temperature 48 C 117 F The lowest heating temperature 35 C 95 F With 110V 60Hz UL power cord Power consumption 800W KH298 Luxury water container big enough for any foot sizes Cleaning and Maintenance Before cleaning you must turn off the device and unplug the power cord from the electric outlet Make...

Page 17: ...urn and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Troubleshooting Problem Cause Solutions Water Jet or waterfall not working Water filter and or waterfall valve is blocked clean up the water filter if necessary Check and clean up the herbal bag basket Heating not working Heating function is turned off It m...

Page 18: ... Turn off the device completely and let it cool down for a while before using it again P2 P3 P4 are present spa program Not allowed to change under preset spa programs P2 P3 P4 Massage not working under P2 P3 P4 Note This product is not intended to diagnose treat cure or prevent any disease Limited Warranty Please contact seller for warranty Limited warranty from manufacturer only for original pur...

Reviews: