malfunction
cause
remedy
6. GS02 on/off cartridge
does not switch
No power
1. Check power supply
2. Check voltage across solenoid
Activate the emergency control.
7. GS02 on/off cartridge
does not switch
Solenoid inoperable
1. Corroded contacts
2. Solenoid defective
3. Breach in the cable
1. Clean contacts
2. Use emergency control, see
Emergency control section
3. If the loading function is not used,
then swap the solenoids for GS02
and G02; note the plugs must also
be swapped
8. floor moves in loading direction
when either loading or unloading is
selected
Emergency control G02 is
in the loading position, the
extreme position
Deactivate the emergency control.
9. floor moves in the loading
direction when loading is selected,
but does not move when unloading is
selected
Plugs are connected the
wrong way round on the
solenoids
Reverse the plugs
10. floor does not move when loading
is selected, but does move when
unloading is selected
See point 6 or point 7
See point 6 or point 7.
1. Check the flow, see page 25.
11. all three floor groups
simultaneously move backwards and
forwards under high pressure when
unloading is selected
Capacity of the system is
insufficient to move the
load.
See point 4d
1. Thaw
2. Remove part of the load
3. Clean the floor once the load has
been removed
12. all three floor groups move
correctly when unloading is selected,
the individual groups move slowly
whereby group 2 and 3 move
together
Capacity of the system is
insufficient to move the
load.
See point 4d
1. Thaw
2. Remove part of the load
3. Clean the floor once the load has
been removed
13. other malfunction
-
Contact your body builder; make sure
you have the system number available
when you do so