10
11
Vedpak 98UK_Version 5_010909
160775
GB
Jump
By pressing this button, the driver will be able to obtain the image
selected under this setting.
QUAD
Obtain image from all camera input in quad picture while pressing
the JUMP button and press again to return the default screen.
SEQ.
Corresponding with “SEQ. Timer Step” setting to jump channel by
time sequence.
CAM A
Obtain image from camera A while pressing the JUMP button and
press again to return the default screen.
CAM B
Obtain image from camera B while pressing the JUMP button and
press again to return the default screen.
CAM C
Obtain image from camera C while pressing the JUMP button and
press again to return the default screen.
CAM R
Obtain image from camera R while pressing the JUMP button and
press again to return the default screen.
CAM A+B
Obtain image from camera A+B in dual picture while pressing the
JUMP button and press again to return the default screen.
CAM C+R
Obtain image from camera C+R in dual picture while pressing the
JUMP button and press again to return the default screen.
CAM A+R
Obtain image from camera A+R in dual picture while pressing the
JUMP button and press again to return the default screen.
CAM R+B
Obtain image from camera R+B in dual picture while pressing the
JUMP button and press again to return the default screen.
CAM A+C
Obtain image from camera A+C in dual picture while pressing the
JUMP button and press again to return the default screen.
CAM C+B
Obtain image from camera C+B in dual picture while pressing the
JUMP button and press again to return the default screen.
CAM R/AB
Obtain image from camera R+A+B in triple picture while pressing
the JUMP button and press again to return the default screen.
CAM R+AB
Obtain image from camera R+A+B in triple picture while pressing
the JUMP button and press again to return the default screen.
Default value is QUAD.
Cam Out
Composite video loop out to recorder, monitor or other device.
QUAD
Recording or viewing from the output device in quad mode
CAM A
Recording or viewing from the output device for CAM A image
CAM B
Recording or viewing from the output device for CAM B image
CAM C
Recording or viewing from the output device for CAM C image
CAM R
Recording or viewing from the output device for CAM R image
Default value is QUAD.
SEQ Time Step
Select Cam A/B/C/R switching time setting value from 02~100
Default value is “02”
RETURN
Return to OSD menu selection screen.