Error message
Cause
Remedy
118 Invalid variable
Transferred variable is invalid
with customized entry.
Select correct variable without
customized entry and transfer
it.
119 No ribbon
During the print order the
ribbon roll becomes empty.
Defect at the transfer ribbon
photocell.
Change transfer ribbon.
Check transfer ribbon photocell
(service functions).
120 Wrong directory
Invalid target directory when
copying.
Target directory must not be
within the source directory.
Check target directory.
121 No label PH2
No label found at the rear
printhead (DuoPrint).
Soiled label photocell.
Labels not inserted correctly.
Insert new label roll.
Clean the label photocell.
Check if labels are inserted
correctly.
122 IP occupied
The IP address was already
assigned.
Assign a new IP address.
123 Print asynchronous
The label photocell do not work
in the order as it is expected
according to print data.
Check label size and gap size.
The settings of the photocell
are not correct.
Check label photocell settings.
Settings of label size and gap
size are not correct.
Check correct loading of label
material.
No label found at the rear
printhead.
Insert new label roll.
Soiled label photocell.
Clean the label photocell.
Labels not inserted correctly.
Check if labels are inserted
correctly.
124 Speed too low
The print speed is too slow.
Increase the speed of
customers' machine.
125 DMA buffer
Communication problem HMI.
Restart the printer.
126 UID conflict
Configuration RFID
programming faulty.
Run RFID initialising.
127 Module not found
RFID module not available.
Check the RFID module
connection.
Please contact your
responsible distributor.
128 No release signal
No print release by higher-level
control (customer machine).
Activate release signal at the
higher-level control.
Summary of Contents for COMPA II
Page 1: ...COMPA II Operating Manual ...
Page 10: ...Introduction Compa II 10 Operating manual 03 20 ...
Page 16: ...Safety Notes Compa II 16 Operating manual 03 20 ...
Page 26: ...Technical Data Compa II 26 Operating manual 03 20 ...
Page 30: ...Installation Compa II 30 Operating manual 03 20 ...
Page 42: ...Load Media Compa II 42 Operating manual 03 20 ...
Page 64: ...Function menu Compa II 64 Operating manual 03 20 ...
Page 104: ...Error Correction Compa II 104 Operating manual 03 20 ...
Page 112: ...Environmentally Friendly Disposal Compa II 110 Operating manual 03 20 ...