DPM III xi
English
93
Service Functions
NOTICE!
So that the distributor res. the manufacturer in case of service can offer fast support the necessary information such
as selected parameters can be taken directly from the service functions menu of the device.
Keys:
,
,
,
,
,
,
,
,
,
,
,
Key:
Photocell parameters:
Start
= Indication of Start photocell (0 or 1) status.
End
= Indication of End photocell (0 or 1) status.
TR
= Indication of transfer ribbon photocell status (0 or 1).
P
= Pressure
Indication of value for compressed-air control (0 or 1).
H
= Head
Indication of value 0 or 1 for the position of machine cover.
0 - cover open
1 - cover closed
Key:
Paper counter:
D:
Indication of printhead attainment in meters.
G:
Indication of module attainment in meters.
Key:
Heater resistance:
To achieve a high print quality, the indicated Ohm value must be set after an exchange of
printhead.
Key:
Printhead temperature:
Indication of printhead temperature. The printhead temperature corresponds normally to the
room temperature. In case the maximum printhead temperature is exceeded, the current print
order is interrupted and an error message appears at the modules display.
Key:
Motor / Ramp:
The higher the '++' value is set, the slower the feeding motor is accelerated.
The smaller the '
− −' value is set, the faster the feeding motor is limited.
This function is often used for high printing speed as the tearing of transfer ribbon can be
prevented.
Key:
Print examples:
Settings:
Printout of all settings such as speed, and transfer ribbon material.
Bar codes:
Printout of all available bar code types.
Fonts:
Printout of all available font types.
Key:
Input/Output:
Indication of signal level which indicates the signal a print order is started.
0
– Low
1
– High
Key:
Online/Offline:
This function is activated e.g. if the transfer ribbon is to be changed. It is avoided that a print
order is processed although the module is not ready. If the function is activated then press the
key
to change between Online and Offline mode. The respective state is indicated in the
display (Standard: Off).
Online:
Data can be received by interface. The keys of the foil keyboard are only active, if you
changed in the Offline mode with key
.
Offline:
The keys of the foil keyboard are still active but received data are not processed. If the
module is again in Online mode then new print orders can be again received.
Summary of Contents for DPM III XI
Page 1: ......
Page 4: ......
Page 5: ...Кратко ръководство и указания за безопасност на изделието Български ...
Page 29: ...Zkrácený návod a pokyny pro bezpečnost produktu Čeština ...
Page 53: ...Kurzanleitung und Hinweise zur Produktsicherheit Deutsch ...
Page 77: ...Quick reference guide and product safety English ...
Page 101: ...Rövid bevezetés és útmutató a termékbiztonsággal kapcsolatban Magyar ...
Page 125: ...Skrócona instrukcja i wskazówki dotyczące bezpieczeństwa wyrobu Polski ...
Page 149: ...Краткое руководство и указания по безопасности изделия Русский ...
Page 173: ......
Page 174: ......