Function Menu
Dynacode II Series
52
Operating Manual
08.16
9.4 Machine Parameters (Continuous Mode)
It is not possible to start printing by the interface. The machine is
always in control mode and the print is released by the control input
Print Start
. The operating mode is normally transferred with each
layout otherwise mode
I/O dynamic continuous
is used as standard
operating mode.
The following modes are available:
IO ST
IO static
The input signal is evaluated, i.e. it is printed as
long as the signal exists. The number of layouts,
which was entered at print start, is printed (level
evaluation of print start signal).
IO ST F
IO static continuous
Corresponds to IO static. Continuous means that
not only a defined number of pieces is processed
but the same layout is printed as long as new data
is transferred by interface.
IO DY
IO dynamic
The external signal is evaluated dynamically, i.e. in
case the direct print module is in 'waiting' mode a
single layout is printed at each signal changing
(flank evaluation of print start signal).
IO DY F
IO dynamic continuous
Corresponds to IO dynamic. Continuous means that
not only a defined number of pieces is processed
but the same layout is printed as long as new data
is transferred by interface.
Test mode
This operating mode corresponds to mode 2. After
the return of the print unit to the zero point of the
machine, however, internally a further cycle is
started (endurance test).
Direct start
A print order is transferred. After termination of
generating process the print order is executed
without an external signal.
Operating mode