Function Menu
Dynacode II Series
64
Operating Manual
08.16
9.16 Service Functions
NOTICE!
So that the distributor res. the direct print module manufacturer
in case of service can offer fast support all necessary
information such as selected parameters can be taken directly
from the device.
H
= Cover switch
Only available at devices with cover switch.
0 = oper cover
1 = closed cover
P
= Pressure
Indication of value 0 or 1 or compressed air control.
R1
= Transfer ribbon rewinding roll
Indication of transfer ribbon rewinding roll status.
4 states are indicated (no marking in photocell, marking from
right, marking from left, marking completely in photocell).
R2
= Transfer ribbon unwinding roll
Indication of transfer ribbon unwinding roll status.
4 states are indicated (no marking in photocell, marking from
right, marking from left, marking completely in photocell).
C
= Carriage
Indication of print carriage position.
ENC = Encocer
Indication of current state of encoder
D:
Indication of printhead attainment in meters.
G:
Indication of direct print module attainment in meters.
To achieve a high print quality, the indicated Ohm value must be set
after an exchange of printhead.
Indication of printhead temperature. The printhead temperature
corresponds normally to the room temperature. In case the maximum
printhead temperature is exceeded, the current print order is
interrupted and an error message appears at the direct print module
display.
Selection of the used transfer ribbon length (300 m, 450 m, 600 m,
900 m or 1000 m). With smaller ribbons, a higher number of cycles
can be reached.
Selection of the coating side of transfer ribbon, either outside or
inside.
Default: Coating outside
Photocell parameters
Laufleistung
Heater resistance
Printhead temperature
Ribbon
Ink side