Number of layouts per print order: 3
Data memory: Off/standard/extended
Ribbon save: On
Trigger input print start: increasing slope
The use of printer variables means that each layout is different and
the direct print module has to generate several parts of the layout
anew, e.g. variable counter.
Each of the 3 layouts which are to print are the same and therefore it
is only necessary to generate the layout once.
Because only 1 print order is send, the direct print module has only to
receive once.
As the print order consists of three layouts, the print order output is
active as long as all 3 layouts are printed.
In dispenser mode dynamic only the slope of the start impulse is
recognised as valid print start signal. However, the impulse should
have a minimum impulse width of 50 ms.
Layout/generation with
module variables
Layout/generation
without module
variables
Data receipt
Print order
Print start/print
Summary of Contents for FLEXICODE 53
Page 1: ...FLEXICODE Operating Manual ...
Page 8: ...Introduction Flexicode 8 Operating Manual 11 19 ...
Page 14: ...Machine Overview Flexicode 14 Operating Manual 11 19 ...
Page 18: ...Operating Conditions Flexicode 18 Operating Manual 11 19 ...
Page 40: ...Installation and Initial Operation Flexicode 40 Operating Manual 11 19 ...
Page 44: ...Operation Panel Flexicode 44 Operating Manual 11 19 ...
Page 94: ...Maintenance and Cleaning Flexicode 94 Operating Manual 11 19 ...
Page 100: ...Signal Diagrams Flexicode 100 Operating Manual 11 19 ...
Page 114: ...Additional Information Flexicode 114 Operating Manual 11 19 ...
Page 116: ...Environmentally Friendly Disposal Flexicode 116 Operating Manual 11 19 ...