Vario II
82
English
Technical data of power supply
Power line voltage and power line frequency:
see type plate
Allowable tolerance of power line voltage:
+6% to
−10% of nominal value
Allowable tolerance of power line frequency:
+2% to
−2% of nominal value
Allowable distortion factor of power line voltage:
<=5%
Anti-Interference measures:
In case your net is infected (e.g. by using thyristor controlled machines) anti-interference measures have to be taken. You can
use one of the following possibilities:
•
Provide separate power supply to our printers.
•
In case of problems please connect capacity-decoupled isolation transformer or similar interference suppressor in front of
our printers.
Stray radiation and immunity from disturbance
Emitted interference according to EN 61000-6-4: 08-2002
•
Interference voltage to wires according to EN 55022: 09-2003
•
Interference field power according to EN 55022: 09-2003
Immunity to interference according to EN 61000-6-2: 03-2006
•
Stray radiation against discharge of static electricity according to EN 61000-4-2: 12-2001
•
Electromagnetic fields according to EN 61000-4-3: 11-2003
•
Fast transient burst according to EN 61000-4-4: 07-2005
•
Surge according to EN 61000-4-5: 12-2001
•
High-frequency tension according to EN 61000-4-6: 12-2001
•
Voltage interruption and voltage drop according to EN 61000-4-11: 02-2005
This is a machine of type A. This machine can cause interferences in residential areas; in this case it can be
required from operator to accomplish appropriate measures and be responsible for it.
Connecting lines to external machines
All connecting lines have to be guided in shielded lines. Shielding has to be connected on both sides to the corner shell.
It is not allowed to guide lines parallel to power lines. If a parallel guiding cannot be avoided a distance of at least 0.5 m has to
be observed.
Temperature of lines between:
−15 to +80 °C.
It is only allowed to connect devices which fulfil the request 'Safety Extra Low Voltage' (SELV). These are generally devices
which are checked corresponding to EN 60950.
Installation of data lines
The data cables must be completely protected and provide with metal or metallised connector housings. Shielded cables and
connectors are necessary, in order to avoid radiant emittance and receipt of electrical disturbances.
Allowable lines
Shielded line:
4 x 2 x 0,14 mm² ( 4 x 2 x AWG 26)
6 x 2 x 0,14 mm² ( 6 x 2 x AWG 26)
12 x 2 x 0,14 mm² (12 x 2 x AWG 26)
Sending and receiving lines have to be twisted in pairs.
Maximum line length:
with interface V 24 (RS232C) - 3 m (with shielding)
with Centronics - 3 m (with shielding)
with USB - 5 m
with Ethernet - 100 m
Summary of Contents for Vario II series
Page 2: ......
Page 4: ......
Page 5: ...Кратко ръководство и указания за безопасност на изделието Български ...
Page 28: ......
Page 29: ...Zkrácený návod a pokyny pro bezpečnost produktu Čeština ...
Page 52: ......
Page 53: ...Kurzanleitung und Hinweise zur Produktsicherheit Deutsch ...
Page 76: ......
Page 77: ...Quick reference guide and product safety English ...
Page 100: ......
Page 101: ...Rövid bevezetés és útmutató a termékbiztonsággal kapcsolatban Magyar ...
Page 124: ......
Page 125: ...Skrócona instrukcja i wskazówki dotyczące bezpieczeństwa wyrobu Polski ...
Page 148: ......
Page 149: ...Краткое руководство и указания по безопасности изделия Русский ...