Vario III Series
Options
11.13 Operating
Manual
65
Press key
to arrive at the next menu item.
Indication of value at which the label is moved so the scanner can
read data onto the label.
Press key
to arrive at the next menu item.
If this parameter is set to 0 (AUTO), the switch on and off position of
scanner is calculated by means of position and height of bar code
onto the label.
If the parameter Scan Length is not 0, so this defines the length of
scan sector. The start of scan sector is then set by the parameter
Scan Offset. The following drawing shows the meaning of parameter.
Figure 12
Press key
to arrive at the next menu item.
With this parameter can be adjusted, at which time the scanning of the
bar code is to be effected - during printing or after printing.
Press key
to arrive at the next menu item.
In scan mode 'after print' the scanner is switched On after the label
was printed. With this value the time can be specified between printing
the label and switching On the scanner.
Press key
to arrive at the next menu item.
In scan mode 'after print' can be specified with this value the time
which is available for scanning the label.
Press key
to arrive at the next menu item.
To use a scanner, the COM2 interface is set to 1.
For more information, please see the separate manual.
Scan offset
Scan length
Scan mode
Scan delay
Scan timeout
Interface