Error message
Cause
Remedy
64 Zero
point
Defective photocell.
Change photocell.
65 Compressed
air
Pressure air is not connected.
Check pressure air.
66 External
releaser
External print release signal is
missing.
Check input signal.
67
Row too long
Wrong definition of column
width res. number of columns.
Reduce the column width res.
correct the number of columns.
68 Scanner
The connected bar code
scanner signals a device error.
Check the connection
scanner/printer.
Check scanner (dirty).
69 Scanner
NoRead
Bad print quality.
Printhead completely soiled or
defective.
Print speed too high.
Increase contrast.
Clean printhead or exchange (if
necessary).
Reduce print speed.
70 Scanner
data
Scanned data does not
correspond to the data which is
to print.
Exchange printhead.
71 Invalid
page
As page number either 0 or a
number > 9 is selected.
Select a number between 1
and 9.
72 Page
selection
A page which is not available is
selected.
Check the defined pages.
73
Page not defined
The page is not defined.
Check the print definition.
74
Format user guiding
Wrong format for customised
entry.
Check the format string.
75 Format
date/time
Wrong format for date/time.
Check the format string.
76 Hotstart
CF
No CF card found.
If option hotstart was activated,
a CF card must be inserted.
Switch off the printer before
inserting the memory card.
77 Flip/Rotate
Selection of print of several
columns and also mirror/rotate.
It is only possible to select one
of both functions.
78 System
file
Loading of temporary hotstart
files.
Not possible.
79 Shift
variable
Faulty definition of shift times
(overlapping times).
Check definition of shift times.
80 GS1
Databar
General GS1 Databar error.
Check definition and parameter
of GS1 Databar code.
81 IGP
error
Protocol error IGP.
Check sent data.