MN99102  042015

– 16 –

Model 99FRD, 102CRD & EZ-66 Oil Burners — Instruction Manual

6.  Repair Parts

For parts not shown or listed, contact factory and/or check separate documentation supplied with appliance/burner unit.

ITEM

PART NO.

DESCRIPTION

99FRD

100CRD

102CRD

1

98022S

1/6HP PSC Motor, 48 M Frame

 

2

82768S

Electrode set (2), –  5"

82776S

Electrode set (2), –  7"

82784S

Electrode set (2), –  9"

82792S

Electrode set (2), –  11"

3

20180S

99FRD/100CRD  5" Air Tube/Combustion Head Assy

20230S

99FRD/100CRD 7" Air Tube/Combustion Head Assy

20313S

99FRD/100CRD 9" Air Tube/Combustion Head Assy

19919S

99FRD/100CRD 11" Air Tube/Combustion Head Assy

21790S

102CRD 5" B Air Tube/Combustion Head Assy

21857S

102CRD 7" B Air Tube/Combustion Head Assy

21881S

102CRD 9" B Air Tube/Combustion Head Assy

21691S

102CRD 11" B Air Tube/Combustion Head Assy

21980S

102CRD 5" C Air Tube/Combustion Head Assy

21998S

102CRD 7" C Air Tube/Combustion Head Assy

22004S

102CRD 9" C Air Tube/Combustion Head Assy

21915S

102CRD 11" C Air Tube/Combustion Head Assy

4

41000S

110V Ignitor

41000S0CAS

110V Ignitor on Baseplate

5

SVC10FFS

Oil Valve  

98289S

Oil Valve Kit with fittings

6

22996S

Fuel Unit A2VA-7116

98750S

Fuel Unit A2VA-3006

23234S

Fuel Unit A2YA-7916

7

34397S

Oil line kit (incl. all oil lines)

8

75564S

Fuel Unit Coupling

9

98100S

99FRD/100CRD/102CRD Air Band Shutter Single Kit

98101S

99FRD/100CRD/102CRD Air Band Shutter Dual Kit

10

5489001S

Nozzle Line adjusting slide

11

51805S

Combustion Head Assy 5"

51854S

Combustion Head Assy 7"

51896S

Combustion Head Assy 9"

51599S

Combustion Head Assy 11"

52316S

Combustion Head Assy 5"

52373S

Combustion Head Assy 7"

52472S

Combustion Head Assy 9"

52183S

Combustion Head Assy 11"

12

50624S

C-Ring & Thumb nut kit

13

50821S

Gasket kit (10  gaskets)

14

14407SES

Cad Cell Kit

15

41DTK01S

Universal Ignitor Terminal Kit (not shown)

16

28605S

Blower wheel / fan 99FRD

28530S

Blower wheel / fan 100CRD

28506S

Blower wheel / fan 102CRD

Summary of Contents for 102CRD

Page 1: ...formation regarding operation of this burner The burner Instruction Manual is intended only for your service technician The burner and heat exchanger must be inspected and started at least annually by...

Page 2: ...pliance per this manual and the appliance instructions see User s information To keep this manual at or near the burner appliance for ready ac cess by the user and service technician To contact the se...

Page 3: ...ng GPH 0 50 to 3 00 2 00 to 3 50 3 00 to 4 50 Delavan Hollow 60 A Delavan Solid 60 B Hollow 70 A Solid 70 B Hago Hollow 60 H Solid 80 B Hollow 70 H Hago Semi solid 45 SS Monarch Hollow 60 NS Semi soli...

Page 4: ...ning sizes are always given in free area This means after deduction for louver obstruction If you can t find the louver reduction for the grilles used assume free area is 20 of total for wood louvers...

Page 5: ...sary clearances to combustible construction including the correct design of thimbles and insulation where penetrating combustible walls Illustrations A to F in Figure 1 show different chamber configur...

Page 6: ...a diameter at least as larger as the minimum width listed For steel cylinder chambers increase this dimension by from 1 to 4 inches 4 Wing walls are not recommended Corbels can be beneficial to heat...

Page 7: ...t flange if needed 7 The end of the air tube should be flush or almost flush with the inside of the combustion chamber wall 8 Verify the air tube is level and inserted the correct depth Adjust if nece...

Page 8: ...s are intended only for negative overfire pressure For pressur ized firing you must obtain a burner with a welded flange designed for use with the specific appliance Failure to comply could result in...

Page 9: ...ng from the housing Replace the gasket if not in good condition 9 Inspect the ignitor contact clips Clean or replace if necessary to ensure reliable contact with the electrodes Install nozzle check el...

Page 10: ...retention ring clamp is firmly against the nozzle adapter shoulder Set initial burner air settings Combustion head 1 The combustion head adjusting slide controls the spacing between the retention ring...

Page 11: ...15 20 0 20 0 20 0 1 25 1 70 2 2 15 2 60 4 0 4 75 2 3 20 2 3 65 5 5 4 5 80 3 25 3 70 5 10 5 100 4 5 70 4 100 6 45 6 100 6 100 5 100 8 65 7 100 6 7 100 9 100 8 100 11 100 10 102CRD 2 air cone B style a...

Page 12: ...d installed and that the fuel flow is unob structed the oil tank is clean and only 1 or 2 heating oil are supplied Failure to supply a reliable oil flow could result in loss of heat and potential seve...

Page 13: ...lation air openings and vent system o Fuel supply line in good condition and sized designed correctly o Oil tank has oil and oil line valves are open o Wiring installed per burner appliance instructio...

Page 14: ...ents a Check smoke It should be zero on the Bacharach scale b Set the appliance flue damper or barometric draft regulator so the draft or pressure in the vent complies with the appliance manufacturer...

Page 15: ...manual with the user Verify the user is aware of all procedures specified in the manuals Verify user will not store or use combustible liquids or materials or contaminants in the vicinity of the burn...

Page 16: ...21998S 102CRD 7 C Air Tube Combustion Head Assy 22004S 102CRD 9 C Air Tube Combustion Head Assy 21915S 102CRD 11 C Air Tube Combustion Head Assy 4 41000S 110V Ignitor 41000S0CAS 110V Ignitor on Basepl...

Page 17: ...arts continued ITEM PART NO DESCRIPTION 99FRD 100CRD 102CRD 17 70200S Universal Primary w Display 70200 48245S Model 48245 Primary w Smart Ignition 4020002S Model 40200 Primary 30 15 30 5020002S Model...

Page 18: ...time you replace a component or disassemble any part of the burner for service maintenance perform a complete operational test after reassembly to verify the burner operates correctly Failure to veri...

Page 19: ...MN99102 042015 19 Model 99FRD 102CRD EZ 66 Oil Burners Instruction Manual...

Page 20: ...ttempt to use gasoline as a fuel for this burner as it is more combustible and could result in a serious explosion Never attempt to burn refuse or use any fuel other than 1 or 2 heating oil ASTM D396...

Reviews: