DESCRIPTION
The TGS-503 8 ounce polyethylene cup is typically used in the applica-
tion of small amounts of material as in touch-up work. The TGS-503 is
suitable for use with all common paints and solvents.
Note
TGS-503 cup can be used with chlorinated solvents. These
solvents will not affect the material used in this cup.
Refer to NFPA-33 publication regarding proper storage
of flammable/combustible materials.
INSTALLATION
Fasten cup to gun by attaching to fluid inlet nipple on gun body. Tighten
only until snug. Lid Assembly (2) should be positioned so vent hole is
to rear. When spraying upwards, it may be necessary to position vent
toward front of gun body.
OPERATION
Strain all materials prior to putting into cup (5). A 90 mesh screen is
recommended for this purpose. Do not fill cup (5) beyond level shown.
See Figure 1.
PREVENTIVE MAINTENANCE
Clean with solvent and wipe with rag.
This lid assembly can be used along with AD-404 (1) adapter for use
with JGA, MBC or other guns with a 3/8" NPS(M) fluid inlet. The EGA
gun uses this lid assembly without the adapter.
One C-422 (6) cup lid is included. Not a purchasable part. Included
in TGS-406 (5).
Replacement
Individual
Part No.
Description
Parts. Req.
1 AD-404
Adapter - Accessory
1
1/4" NPS(M) x 3/8" NPS(F)
2 TGS-401
Lid Assembly
1
3 TGS-4-K5
Gasket (Kit of 5)
1
4 TGS-6-K5
Fluid Tube 4" (Kit of 5) 1
5 TGS-406
Cup and Cover Assembly
1
(Polyethylene)
6 ----
Cup Lid
1
Ref.
No.
Figure 1
3
2
Keep vent
hole open
Do not fill above
250 ml line
1/4 NPS (F)
6
4
5
1
IMPORTANT! DO NOT DESTROY
It is the Customer's responsibility to have all operators and service personnel read and understand this manual.
Contact your local DeVilbiss representative for additional copies of this manual.
READ ALL INSTRUCTIONS BEFORE OPERATING THIS DEVILBISS PRODUCT.
EN
SERVICE MANUAL
TGS-503
8 OUNCE SUCTION FEED CUP