1. Open Cover for Raytek Sensor, loosen and remove wire from terminals shown below.
2. Undo wires from two wire nuts, as shown.
3. Loosen nut on pyrometer side, and remove wires from housing.
4. Open enclosure on top of heat sink, and isolate wires for laser (black/red leads)
5. Clip leads, leaving enough wire to strip and re-connect with crimp connections
6. Loosen and remove standoffs
7. Remove insulating plate
8. Remove heat sink, then remove pyrometer.
Replacement of
N
ew Pyrometer Sensor
Summary of Contents for BGK AutoCure 6000-2216