9.
Install new pyrometer into heat sink, making sure to adjust fit using varnish tape
wrapped on the
outside.
10.
Install heat sink onto lower insulators
11.
Install intermediate plate
12.
Crimp laser leads to leads in pyrometer bundle – red to green and brown to black.
13.
Install standoffs
14.
Replace cover and tighten nuts.
15.
If new pyrometer, replace grommet into side of housing.
16.
Reconnect leads in Raytek sensor housing using schematic in Step 1.
17.
Reconnect wires in wire harness as shown above.
1. Open Housing and loosen 4 terminals to remove pyrometer. Loosen 4 terminals to remove
connection to AutoCure Arm as shown below.
2. Open New Housing, and loosen 4 terminals as shown above to remove pyrometer.
3. Disconnect wires in wire nuts.
4. On New Housing, Loosen and remove nut, grommet, and three washers on thermocouple
side. Loosen and remove nut and all washers on AC arm side.
5. Unmount housing and replace with new housing.
6. Install nut, grommet and 2 washers onto Thermocouple leads, as shown below.
Black
Replacement of Pyrometer Controller