EN
www.carlisleft.com
77
-
3345 R1.1 (06/2022)
46 / 62
6. Assembly instructions:
Begin the assembly of the central body axis by mounting the needle seals (1) and the O
-
rings (2) to the
distance pieces. Press the seals (1) in place using a clean flat surface, then check to make sure that the
seal is flush against the edges of the distance piece.
There are a total of 6 of each seal and O
-
ring that are mounted to the different distances. Note the
difference between the needle guides for the inlet (3) and return (4) channels.
Lightly lubricate the O
-
ring (5) before mounting the needle guides in the central body axis (6). Mount the
distance rings (7) in place. Lightly lubricate the O
-
rings (8) then mount the upper needle guides (9) into the
central body axis (6). Tool 6004 0154 10 can be used to push the parts in place, see page 16.
2
2
1
1
5
6
3
4
5
7
7
8
8
6
9
9
9