32
© Carlo Gavazzi A/S
The indicator lights are implemented in exactly the same housing and holder as the sensors, and
they are mounted in the same way� There is a simple two-wire point-to-point connection between the
sensor and the indicator light�
The new 3-colored Dupline
®
powered LED Indicator must be connected to the same L1 bus as the
sensor� Do not connect this LED indicator GP6265 230x directly to the sensor with a 2-wire point to
point� It will not work�
Master / Slave CPM
Fig. 20 : Car Park Monitor - GP 3482 9091 724
This DIN-rail mounted configurable device is the intelligent part of the system� The purpose of the
CPM is to monitor via the Dupline
®
bus a configurable range of sensors, detect the number of open
spaces and send the result to be shown on the connected display� Normally, a CPM is needed for
every display, but in case two or more displays must show the same information it is possible to use
the same CPM for these�
Parking Guidance System Displays
1 Arrow
GP6763 0106 (A) (A = outdoor version)
1 Arrow + HCP (icon) (Right)
GP6763 0107 (A) (A = outdoor version)
1 Arrow + HCP (icon) (Left)
GP6763 0108 (A) (A = outdoor version)
1 Arrow + 2 Digits
GP6763 0109 (A) (A = outdoor version)
1 Arrow +1 Digit + HCP (icon) (Right)
GP6763 0110 (A) (A = outdoor version)
1 Arrow +1 Digit + HCP (icon) (Left)
GP6763 0111 (A) (A = outdoor version)
8 Characters
GP6763 0112 (A) (A = outdoor version)
8 Char HCP (icon) (Right)
GP6763 0113 (A) (A = outdoor version)
8 Char HCP (icon) (Left)
GP6763 0114 (A) (A = outdoor version)
9 Characters
GP6763 0115 (A) (A = outdoor version)
3 Char Arrow
GP6763 0116 (A) (A = outdoor version)
These are the official displays we have in our range� If other display types are needed, high bright
displays, displays with special text or even combined displays, please contact Dupline support or feel
free to contact our display supplier directly�
There are several types of displays available for the parking guidance system� The number of digits
varies, some are with symbol for disabled people, some can show text (e�g� “FULL”) and some are for
outdoor installations� Which one to choose depends on the location, task and budget�
As mentioned earlier, it is the CPM which sends the number of open spaces to the display via a
RS485 2-wire connection� Most displays are configurable in terms of how to display the values, but
normally “0” open spaces are indicated with red crosses on the display� In case there are available
spaces, the number is shown on the display together with a dynamic green arrow pointing in the right
direction�