Essential information
WM15 - User manual | CARLO GAVAZZI Controls SpA
LCD display
Home page
The unit may display the default measurement pages when the Home button is pressed (starting from any measurement page) or after no
operation has been performed for five minutes, if the screensaver is enabled and the screensaver type is set by UCS to “Home page” (default
value).
Notes:
if you select a page that is not available in the set system, the unit displays as its home page the first available page. In MID models the
home page cannot be changed and displays the active energy meter.
Backlight
The WM15 unit is equipped with a backlight system. You can set whether the backlight shall always be ON or whether it should automatically
switch off after a given interval has elapsed since a button was pressed (1 to 60 minutes)
.
Screensaver
If the SCREENSAVER function is enabled (default setting), after 5 minutes have elapsed since a button was pressed the unit will display the
home page if the screensaver type is “Home page” (default setting), or it shall activate the slideshow function, which displays the selected
pages on a rotating basis
Notes:
the screensaver type and the slideshow function with the relevant pages can only be set up through the UCS software or the UCS
Mobile app. In MID models the screensaver setting is “Homepage” and cannot be changed.
Page filter
The page filter makes it easier to use and browse the measurement pages. When you use the
/
buttons, the unit shall only display
the pages you are most interested in, which can be selected through the UCS software or the UCS Mobile app.
Note:
to display all the pages without using the UCS software or app, you can disable the page filter from the SETTINGS MENU
(DISPLAY →
PAGE FILTER → OFF)
. By default, the pages included in the filter are: 1, 10, 13, 16, 17, 21, 22, 26, see “Measurement pages” on page 14.
Restoring the factory settings
Restoring the settings using the RESET menu
From the RESET menu you can restore all the factory settings. At start-up the
QUICK SET-UP
and WIRING CHECK menu shall be available
again.
Notes:
meters are not reset. In MID models you cannot reset the CT current transformer ratio (CT RATIO).
Restoring the settings using the reset button
Press for at least five seconds the reset button (located near the current inputs) to access the menu, restore all the factory settings and reset
all meters (total and partial).
Note:
in MID models the reset can only be performed if the energy meter has not exceeded 1 kWh. Before sealing the terminal, you can then
correct any CT current transformer setting errors (CT ratio), reactivating the MID programming menu at the next switch-on.
Summary of Contents for WM15
Page 1: ...WM15 Power analyser for three phase systems USER MANUAL ...
Page 25: ...WM15 Analizzatore di potenza per sistemi trifase MANUALE UTENTE ...
Page 49: ...WM15 Netzanalysator für Dreiphasensysteme BETRIEBSANLEITUNG ...
Page 73: ...WM15 Analyseur de puissance pour systèmes triphasés MANUEL D EMPLOI ...
Page 97: ...WM15 Analizador de potencia para sistemas trifásicos MANUAL DE USUARIO ...
Page 121: ...WM15 Effektanalyseinstrument til trefasede systemer BRUGERMANUAL ...
Page 145: ...WM15 用于三相系统的功率分析仪 用户手册 ...
Page 147: ...3 WM15 用户手册 CARLO GAVAZZI Controls SpA 维护和处理 22 测量问题 22 警报 22 通信问题 22 显示问题 22 ...
Page 169: ...WM15 三相系統用電力分析儀 使用者手冊 ...
Page 171: ...3 WM15 使用者手冊 CARLO GAVAZZI Controls SpA 維護與廢棄 22 度量問題 22 警報 22 通訊問題 22 顯示問題 22 ...